Electrical Connection - Electric Dryer (4-Wire Cord) - Electrolux 134709300 Installation Instructions Manual

Front-load gas & electric dryer
Table of Contents

Advertisement

Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
1.
Turn off power supply to outlet.
2.
Remove the screw securing the terminal block
access cover in the lower corner on the back of
the dryer.
3.
Install a UL-approved strain relief according
to the power cord/strain relief manufacturer's
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
4.
Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 14-30 type ST or
SRDT, through the strain relief.
5.
Disconnect the internal (BLACK) dryer harness
ground wire from the (GREEN) ground screw
next to the terminal block.
6.
Attach the ground (GREEN) power cord wire
to the cabinet with the ground (GREEN) screw.
Tighten the screw securely.
7.
Move the internal dryer harness ground
(BLACK) wire to the terminal block and attach
it along with the neutral (WHITE) power cord
wire conductor to the center, SILVER colored
terminal on the terminal block. Tighten the
screw securely.
8.
Attach the RED and BLACK power cord
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
9.
Follow manufacturer's guidelines for firmly
securing the strain relief and power cord.
10.
Reinstall the terminal block cover.
Installation Instructions
30 AMP
NEMA 14-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
Move internal ground (BLACK)
wire to neutral (SILVER)
terminal for 4-wire system.
GREEN
ground screw
GREEN
ground wire
Neutral
(WHITE wire)
Ground
(GREEN wire)
Access cover
screw
Terminal
block
Line 2
(BRASS terminal)
Neutral
(SILVER terminal)
Line 1
(BRASS terminal)
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Neutral
terminal
WHITE
neutral wire
BLACK
or RED
power wire
BLACK or
RED power wire
13

Hide quick links:

Advertisement

Table of Contents
loading