Step 5—FINAL WIRING
Bring all damper and sensor wires together at the Infinity Damper
Control. Make all system wiring connections as indicated in Fig. 9.
The two ABCD bus connections on the Infinity Damper Control
SET SCREW
MOUNTING HUB
CLS COM OPN
CLS
COM
OPN
ANTI-ROTATION
MOUNTING SCREW (5/16")
C03024
/ " STEEL STRAP
1
2
A95130
S-LOCK
DRIVE
ZONE
DAMPER
A92478
A95131
FLEXIBLE
DUCT
ACTUATOR
HOUSING
Fig. 5 — Round Flexible Duct Work
Fig. 6 — Insulated Round Flexible Duct Work
FIBROUS
GLASS
DUCTWORK
Fig. 7 — Rectangular Fibrous Glass Duct Work
Fig. 8 — Insulated Rectangular Fibrous Glass Duct
are in parallel with each other. Use either terminal block to connect
the Zoning User Interface, Smart Sensor(s), variable-speed indoor
unit and 2-speed communicating outdoor unit (if applied). If more
than four zones are required (up to 8 zones maximum), see
Step—6 and Fig. 10 for Additional Damper Control Board Setup
for Zones 5-8.
VENTILATOR WIRING — The Infinity Damper Control can
control a Carrier Heat Recovery Ventilator or Energy Recovery
Ventilator (HRV / ERV). Connect the four wires from the
ventilator control board (see ventilator installation instructions for
details) to the connector labeled (YRGB). This label identifies the
color of the wire to match the ventilator wire colors (Y=yellow,
R=red, G=green, B=blue or black). If you have two Infinity
Damper Controls, connect the ventilator to the control for zones 1
through 4.
LEAVING AIR TEMPERATURE / HEAT PUMP TEM-
PERATURE (LAT/HPT) SENSORS — These inputs on the
Infinity Damper Control are used only for diagnostic purposes and
4
ZONE
DAMPER
/ " STEEL STRAP
1 2
FIELD
SUPPLIED
SCREWS
2" TO 3"
1 / " TO 2"
1 2
INSULATION
Work
A95132
A95133
ZONE
DAMPER
A92480
A95134

Advertisement

Table of Contents
loading

Table of Contents