Advertisement

Inadequate installation and/or operation of a CO
machine and CO
WARNING
Always follow the instructions from this manual, from your CO
supplier and from local authorities.
2.3

INDOOR USE

The MAGICFX
CO2JET II is designed for outdoor use and use in well-ventilated indoor
®
spaces. When used indoors, make sure you take the necessary preparations. These
preparations could include, but are not limited to:
Consulting your CO
Calculating the reduction of oxygen for the indoor space.
Checking the location for spots where CO
preventive actions.
Installing CO
2
Do not use the MAGICFX
DANGER
spaces. Exposure to high levels of CO
headache, nausea, loss of consciousness or even death.
2.4

RIGGING

Please follow the European and national guidelines for safe rigging and trussing.
2.5

NOISE LEVEL

The environmental noise level measured at 100 cm (39,37 in) from the product is 90
dB(A). This level of noise is only reached during the short shooting instances.
Therefore hearing protection is not necessary.
Do not operate the MAGICFX® CO2JET II close to yourself or to
others for a long period of time. If you experience any hearing
WARNING
loss or ringing in the ears, you should immediately stop using the
unit.
All manuals and user guides at all-guides.com
cylinders can lead to death or serious injury.
2
supplier.
2
monitoring devices that will warn for hazardous CO
MAGICFX® CO2JET II — User and Installation Manual
could accumulate and taking
2
CO2JET II in poor ventilated confined
®
can cause symptoms like
2
powered
2
2
levels.
2
9