(www.sew-eurodrive.com). Consult SEW-EURODRIVE if you are unclear about any of the information in this documentation, or if you require further information. You can also order the printed documentation from SEW-EURODRIVE. Underlying standards The safety assessment of the encoder is based on the following standards and safety...
Read the operating instructions and the adden- dum to the operating instructions before you start working with the unit. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
You must comply with the information contained in these operating instructions to en- sure safe operation of the electric motors and to achieve the specified product charac- teristics and performance features. SEW-EURODRIVE does not assume liability for in- jury to persons or damage to equipment or property resulting from non-observance of these operating instructions.
Removing the required protection cover or the housing without authorization, improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property. Refer to the detailed operating instructions for additional information. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
13849-1 and all other standards, directives and laws specified in this documentation. • The content of the publication "Addendum to the Operating Instructions: Functional Safety for Synchronous CMP Servomotors". • The content of the detailed operating instructions. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
A higher-level, safe evaluation unit is required in addition, as the encoder with its encoder-internal diagnostic function is not able to trigger re- sponses such as initiating a safe status on its own initiative. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
In this case, the tension force vector of the slings must not exceed a 45° angle in accordance with DIN 580. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
Whenever changes to normal operation occur, such as increased temperatures, noise, vibrations, determine the cause and consult the manufacturer. See the notes in chapter "Startup" of the detailed operating instructions. 2.10 Inspection/maintenance Observe the notes in section 8, "Inspection/Maintenance". Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
SEW-EURODRIVE drives can be supplied with safety-rated components on request. SEW-EURODRIVE indicates such an integration by the FS mark and a number on the nameplate. The number is a code that indicates which components in the motor are safety-related.
The FS logo on the nameplate is based on the combination of safety-related compo- nents that is installed, see code table above. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
Mechanical installation Retrofitting a safe encoder Mechanical installation This chapter contains no special information about safety-rated components. Retrofitting a safe encoder Only SEW-EURODRIVE may retrofit a safety-rated encoder. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
A bag containing the following information is attached to the motor: • Safety notes • Wiring diagram Observe these notes. Note the information and explanations about correct wiring in the corresponding operat- ing instructions. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
The rated speed of the motor in a gearmotor can be higher than the permitted, input speed of the gear unit. Limit the maximum speed at the servo inverter. For information on the procedure, refer to the documentation of the servo inverter. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
"Inspection/Maintenance". A working air gap that exceeds the permitted maximum value can cause encoder errors or destroy the encoder. Encoder malfunctions are displayed at the inverter with a corresponding error message. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
Switch both, the DC and AC voltage sides; observe Brake is switched on AC voltage side time lag wiring diagram Noise/squeaking near Brake parameters set incorrectly in the inverter Check brake release and application times the brake Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
When a BY brake is used, the working air gap must be measured at regular inter- vals, which are specified in the "Synchronous Servomotors" operating instructions in chapter "Inspection/Maintenance". A working air gap that exceeds the permitted maximum value can cause encoder errors or destroy the encoder. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
Certain demands on the mechanical coupling of the encoder system to the motor must be met so that the encoder can be used for safety-relevant tasks. SEW-EURODRIVE assumes responsibility for the delivered motor with safety-rated en- coder in terms of compliance with the functional safety regulations. Safety-relevant con- nection elements are sealed in order to be able to ensure that the delivery condition is not changed, see following figures.
Page 23
SEW-EURODRIVE to inform the respective customers/operators in the event of product defects. Consistent retraceability by SEW-EURODRIVE is no longer ensured if you perform work on safety-rated encoder system, e.g. if you replace or retrofit encoders. This is why we strongly suggest that you establish your own retraceability procedure and/or to support the SEW-EURODRIVE measures.
1) The specified value refers to a diagnostics coverage of 90% that must be achieved by an encoder evaluation unit. Diagnostics must be performed within the process response time. 2) Ambient temperature 40 °C Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
1) Diagnostics must be performed within the process response time. 2) In the encoder evaluation unit, signals A, A, B and B must be high-resistance (> 1 kΩ) to the supply voltage and 0 V. Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
PDQXDO HWF PXVW EH PHW RYHU WKH HQWLUH SURGXFW OLIH F\FOH Bruchsal Johann Soder Place Date Managing Director Technology a) b) a) Authorized representative for issuing this declaration on behalf of the manufacturer b) Authorized representative for compiling the technical documents Functional Safety – Synchronous Servomotors CMP40-112, CMPZ71-100...
Page 28
SEW-EURODRIVE—Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 76642 BRUCHSAL GERMANY Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com...