Contents Contents General information........................ 5 About this documentation .................... 5 Structure of the safety notes ................... 5 1.2.1 Meaning of signal words ................ 5 1.2.2 Structure of section-related safety notes............ 5 1.2.3 Structure of embedded safety notes .............. 6 Rights to claim under limited warranty ................ 6 Product names and trademarks.................. 6 Copyright notice ...................... 7 Other applicable documentation .................. 7...
Page 4
Contents 4.5.1 Before you start .................... 27 4.5.2 General installation notes for encoders............ 27 Service ............................. 28 Modification/changes to the device................ 28 Waste disposal...................... 28 Replacement of the DAE70B/71B/72B encoder signal split box........ 29 Technical data......................... 30 General technical data .................... 30 Dimension drawing ....................... 30 DAE70B/71B/72B plug connectors ................ 31 6.3.1 Connector assignment X26................
General information About this documentation General information About this documentation The documentation at hand is the original. This documentation is an integral part of the product. The documentation is intended for all employees who perform work on the product. Make sure this documentation is accessible and legible. Ensure that persons respon- sible for the systems and their operation as well as persons who work on the product independently have read through the documentation carefully and understood it.
General information Rights to claim under limited warranty Meaning of the hazard symbols The hazard symbols in the safety notes have the following meaning: Hazard symbol Meaning General hazard Warning of dangerous electrical voltage Warning of hot surfaces Warning of risk of crushing Warning of suspended load Warning of automatic restart 1.2.3...
Safety notes Preliminary information Safety notes Preliminary information The following general safety notes serve the purpose of preventing injury to persons and damage to property. They primarily apply to the use of products described in this documentation. If you use additional components, also observe the relevant warning and safety notes.
Safety notes Designated use Specialist for elec- Any electrotechnical work may be performed only by electrically skilled persons with a trotechnical work suitable education. Electrically skilled persons in the context of this documentation are persons who are familiar with electrical installation, startup, troubleshooting, and main- tenance of the product who possess the following qualifications: •...
Safety notes Installation/assembly Installation/assembly Ensure that the product is installed and cooled according to the regulations in the doc- umentation. Protect the product from excessive mechanical strain. The product and its mounted components must not protrude into the path of persons or vehicles. Ensure that com- ponents are not deformed and that insulation spaces are maintained, particularly dur- ing transportation.
The TF temperature sensor can be connected to terminal X26 of the DAE71B en- coder signal split box. 3.1.3 DAE72B (RES) • Splitting of the resolver signals for the following device combinations: – Synchronous motors (e.g. CMP..) with resolver from SEW-EURODRIVE, ® ® MOVIDRIVE B with MOVISAFE UCS14B/PS (compact design) –...
Device structure Scope of delivery Scope of delivery DAE70B/71B/72B encoder signal split box. • Part number DAE70B (INK): 18243797 • Part number DAE71B (SSI): 18243800 • Part number DAE72B (RES): 28232232 3.2.1 Optional scope of delivery Cable sets 1 – 9 SEW‑EURODRIVE offers product-specific cable sets that facilitate configuration. The encoder cables of each cable set have a fixed length of 1.5 m.
Page 13
Device structure Scope of delivery ® Cable set 4 (for connecting DAE70B/71B to MOVIDRIVE B with DIP11B and ® DEH21B and MOVISAFE DCS..B). Cable set 4 Part num- Encoder Function cable/part number 28203038 DAE83B/ Connection between DAE70B/71B and ® MOVISAFE DCS..B 18141749 ®...
Page 14
Device structure Scope of delivery ® Cable set 8 (for connecting DAE72B to MOVIDRIVE B with DEU21B and ® MOVISAFE UCS..B). Cable set 8 Part num- Encoder Function cable/part number ® 28221338 DAE87B/ Connection between DAE72B and MOVISAFE UCS..B 18177859 ® DAE88B/ Connection between DAE72B and MOVIDRIVE B...
Page 15
Device structure Scope of delivery DAE..B encoder cable INFORMATION The length of the encoder cables listed here can be configured from 0.8 m to 6 m. DAE80B encoder cable [II] 4135050891 DAE80B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 15-pole ®...
Page 16
Device structure Scope of delivery DAE82B encoder cable [II] 4135054347 DAE82B Connection Part number [II] D-sub socket, 9-pole D-sub connector, 9-pole ® 18131123 DAE70B/71B:X72 MOVISAFE UCS..B (compact or multi-axis type): • • DAE83B encoder cable [II] 4135054347 DAE83B Connection Part number [II] D-sub socket, 9-pole D-sub connector, 9-pole...
Page 17
Device structure Scope of delivery DAE84B encoder cable [II] 4135050891 DAE84B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 9-pole ® 18143210 DAE70B/71B:X71 MOVIDRIVE B: • DEH21B:X62 • DIP11B:X62 DAE85B encoder cable [II] 4135054347 DAE85B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 9-pole ®...
Page 18
Device structure Scope of delivery DAE86B encoder cable [II] 4135054347 DAE86B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 15-pole ® 18157351 DAE70B/71B:X71 MOVIDRIVE B: • DEU21B:X14 DAE87B encoder cable [II] 4135054347 DAE87B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 9-pole ®...
Page 19
Device structure Scope of delivery DAE88B encoder cable [II] 4135054347 DAE88B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 9-pole ® 18177735 DAE72B:X71 MOVIDRIVE B: • DER21B:X15 DAE89B encoder cable [II] 4135054347 DAE89B Connection Part number [II] D-sub socket, 15-pole D-sub connector, 9-pole ®...
Device structure Device structure 3.4.2 DAE72B OFF ON DAE72B 15973224075 View of the bottom of the device ® Connection of MOVISAFE UCS..B ® ® Connection MOVIDRIVE B, MOVIAXIS Resolver connection Shield terminal 8 DIP switches (in two rows, one behind the other, pos. 1 – 4) for switch- ®...
Installation Before you start Installation Before you start Observe the following note before installing or removing an option: NOTICE Electrostatic discharge. Damage to electronic components. • Disconnect the inverter from the power. Disconnect the DC 24 V supply and the line voltage. •...
Installation Connection and terminal description of the DAE70B/71B/72B option Description Terminal DAE70B (INK) DAE71B (SSI) DAE72B (RES) DIP switch Assignment Assignment Assignment X72: 9-pin D-sub socket X72:1 N. C. N. C. N. C. • DAE70B/71B: X72:2 REF− ® Connection of MOVISAFE DCS..B X72:3 N.
Installation Measures for electromagnetic compatibility (EMC) ® For operation of the DAE72B encoder signal split box with MOVIDRIVE B, you have to set the DIP switches. Proceed as follows: 1. Open the DIP switch cover at the bottom of the DAE72B encoder signal split box. Set the DIP switches according to the label attached to the side of the housing (see the following figure).
– At the metal clamp/strain relief at the bottom of the encoder signal split box • Observe the notes in chapter "Measures for electromagnetic compatibility (EMC)". • Note that only resolvers from SEW-EURODRIVE are permitted on the DAE72B encoder signal split box. Manual – DAE70B/71B/72B Encoder Signal Split Box...
Page 28
Service Modification/changes to the device Service Modification/changes to the device • Hardware changes Changes to the module DAE70B/71B/72B option may only be carried out by SEW‑EURODRIVE. • Repair Only SEW‑EURODRIVE is authorized to repair the DAE70B/71B/72B option. INFORMATION Any right to claim under limited warranty becomes void if the user manipulates the device internally (e.g.
Service Replacement of the DAE70B/71B/72B encoder signal split box Replacement of the DAE70B/71B/72B encoder signal split box Proceed as follows: 1. Before replacing the DAE70B/71B/72B option, you must de-energize the respec- tive system (machine) and any devices connected to the DAE70B/71B/72B option. 2.
Technical data General technical data Technical data General technical data DAE70B/71B/72B Ambient temperature −10 °C to +60 °C Climate class 3K3 (EN 60721-3-3) Storage temperature −25 °C to +80 °C Degree of protection IP20 (EN 60529) Dimension drawing DAE70B 29.8 22.5 98.5 9007203390599435 Dimensions in mm. Manual –...
Technical data DAE70B/71B/72B plug connectors 6.3.3 X71 pin assignment Type: 15-pin D-sub connector. Assignment DAE70B (incremental, sin/cos) DAE71B (SSI) DAE72B (RES) CLK+ N. C. DATA + DATA + N. C. N. C. N. C. REF+ TF_REF TF_REF TF_REF N. C. N.
Index Index DAE72B............ 11 Device structure Assembly DAE70B/71B .......... 21 Safety notes ........... 10 DAE72 ............ 22 Nameplates ............ 20 Device structure of encoder signal split box Cable sets 1 to 9 .......... 12 Type designations and device features.. 11 Connecting the position and velocity sensors ..
Page 34
Index DAE72B............ 20 Transportation .......... 9 Notes Scope of delivery .......... 12 Designation in the documentation .... 5 Optional ............ 12 Meaning of the hazard symbols ....... 6 Section-related safety notes ........ 5 Notes for using the DCS..B option ...... 23 Service ..............
Page 36
SEW-EURODRIVE—Driving the world SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Str. 42 76646 BRUCHSAL GERMANY Tel. +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com...
Need help?
Do you have a question about the DA70B and is the answer not in the manual?