Page 2
0.15 – 0.6 mm. If the working air gap exceeds 0.6 mm, the brake will have to be replaced. The working air gap cannot be adjusted. Revision of the Operating Instructions – Synchronous Servomotors CMP40 - 100, CMPZ71 - 100...
Page 3
4. Release and apply the brake electrically. When doing so, measure the stroke ∆H of the pressure plate at the studs. This stroke ∆H corresponds to the working air gap. ΔH 4386101131 Revision of the Operating Instructions – Synchronous Servomotors CMP40 - 100, CMPZ71 - 100...
Page 4
8. Close the two boreholes with new closing caps [1]. The following table shows the part numbers for the replacement closing caps: Brake sizes Part number BY2, BY4 1328 148 8 1322 534 0 4386103563 Revision of the Operating Instructions – Synchronous Servomotors CMP40 - 100, CMPZ71 - 100...