Group 7: Ac Drive And Motor Parameters; Identity Code Of Ac Drive; Rated Current Of Ac Drive; Full-Load Current Of Motor - Delta Electronics AC Drive VFD-F Series User Manual

Vfd-f series
Table of Contents

Advertisement

VFD-F Series

5.8 Group 7: AC Drive and Motor Parameters

07 - 00

Identity Code of AC Drive

Settings
This parameter displays the AC drive model code.
This parameter is read-only.
07 - 01

Rated Current of AC Drive

Settings
This parameter displays rated output current of the AC drive. The following chart may be
used to look up the identity code, current, and hp of your drive.
230V series
KW
HP
Pr.07-00
Rated current (A)
Max. Carried Freq.
Min. Carried Freq.
Factory Setting
460V series
KW
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
HP
1.0 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 175 215 250 300
Pr.07-00
05 07 09 11 13 15 17 19 21 23 25 27 29 31 33
Rated Current (A) 2.7 4.2 5.5 8.5 13 18 24 32 38 45 60 73 91 110 150 180 220 260 310 370 460
Max. Carried Freq.
Min. Carried Freq.
Factory Setting
This parameter is read-only.
07 - 02

Full-load Current of Motor

Settings
This parameter selects the full load current of the motor.
Pr7-02 = (full load motor current / drive rated current)
Example: If the rated current of AC drive is 150A, full-load current of motor is 120A, then
Pr.7-02 should be set to 80%.
Display by model type
Display by model type
0.75
1.5
2.2
1
2
3
4
6
8
5
7
11
10KHz
4KHz
9KHz
10KHz
4KHz
9KHz
30~120%
3.7
5.5
7.5
5
7.5
10
10
12
14
17
25
33
9KHz
3KHz
6KHz
5-36
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Factory Setting: ##
Factory Setting: ##
11
15
18.5
15
20
25
16
18
20
49
65
75
9KHz
3KHz
6KHz
90
110 130 160 185 220
35
37
6KHz
2KHz
4KHz
Factory Setting: 100%
22
30
37
30
40
50
22
24
26
90
120
145
6KHz
2KHz
4KHz
39
41
43
45
Unit: 1