3.4 Control Terminals

SINK/NPN Mode
Multi-function
Input Terminal
Internal Circuit
DCM

Terminal symbols and functions

Terminal Symbols
FWD
Forward-Stop command
REV
Reverse-Stop command
EF
External fault
MI1
Multi-function Input 1
MI2
Multi-function Input 2
MI3
Multi-function Input 3
MI4
Multi-function Input 4
MI5
Multi-function Input 5
MI6
Multi-function Input 6
MI7
Multi-function Input 7
MI8
Multi-function Input 8
+24V
DC Voltage Source
DCM
Digital Signal Common
Multi-function Relay1
RA 1
output (N.O.) a
Multi-function Relay1
RB 1
output (N.C.) b
Multi-function Relay1
RC 1
common
Multi-function Relay2
RA 2
output (N.O.) a
Multi-function Relay2
RB 2
output (N.C.) b
Multi-function Relay2
RC 2
common
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
+24V
Terminal Functions
SOURCE/PNP Mode
Multi-function
Input Terminal
+24V
Factory Settings
Factory setting: Multi-step speed command 1
Factory setting: Multi-step speed command 2
Factory setting: Multi-step speed command 3
Factory setting: Multi-step speed command 4
Factory setting: RESET
Factory setting: JOG
Factory setting: Accel/Decel prohibit
Factory setting: Accel/Decel time switch 1
(+24V, 20mA), used for source mode.
Used as common for digital inputs and used
for sink mode.
1.5A(N.O.)/1A(N.C.) 240VAC
1.5A(N.O.)/1A(N.C.) 24VDC
Refer to Pr.03-00 to Pr.03-01
3-9
VFD-F Series
DCM
Internal Circuit
3

Hide quick links: