Ac/Dc Disconnection Switch; Power Socket (Ac) - Delta Electronics RPI M6A Installation And Operation Manual

Table of Contents

Advertisement

4.4.3 AC/DC disconnection switch

Fig. 4.2:
AC/DC disconnector
Intended purpose
By turning the AC/DC circuit breaker, the connections from the
inverter to the grid and the solar modules are disconnected or
closed. The disconnection of the connections is a basic prerequi-
site for safe working on the inverter.
Technical design
Rotary switch with two positions: OFFand ON
How does it work?
The inverter is disconnected from the grid (AC) and the solar
modules (DC) when the AC/DC disconnection switch is in posi-
tion OFF.
Fig. 4.3:
AC/DC isolating switches in the ON position
The inverter is connected to the grid (AC) and the solar modules
(DC) when the AC/DC disconnection switch is in position ON.
Installation and Operation Manual for Power Inverter RPI M6A M8A M10A EU V4 EN 2020-07-13

4.4.4 Power socket (AC)

Fig. 4.4:
AC socket
Intended purpose
The power supply socket is used to connect the inverter to the
grid to supply AC power to the grid
Feeding AC power into the public grid.
Providing power for the display from the grid when power is
not available from the solar modules.
Grid types that can be used
3-phase networks with neutral conductor: 3P4W (L1, L2,
L3, N, PE)
3-phase networks without neutral conductor: 3P3W (L1, L2,
L3, PE).
AC plug
Inverter
M6A, M8A, M10A
Table 4.1.: AC plug used
The AC plug is included in the scope of delivery.
4 Product overview
Electrical connections
Type of AC plug
China Aviation Optical-Electrical
Technology Co. PVE5T50KP73