Specifications For Brake Unit - Delta Electronics AC Drive VFD-F Series User Manual

Vfd-f series
Table of Contents

Advertisement

B.1.2 Specifications for Brake Unit
Voltage Class
□□□□
Model Number VFDB-
Max. Motor Power (kW)
Max. Peak Discharge
Current (A) 10%ED
Continuous Discharge
Current (A)
Brake Start-up Voltage
(DC)
DC Voltage
Heat Sink Overheat
Alarm Output
Power Charge Display
Installation Location
Operating Temperature -10 ℃ ~+50 ℃
Storage Temperature
Humidity
Vibration
Wall-mounted Enclosed Type
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
230V Series
2015
2022
15
22
40
60
15
20
330/345/360/380/400/415
±3V
200~400VDC
Temperature over +95°C (203
RELAY contact 5A120Vac/28Vdc(RA, RB, RC)
Blackout until bus (+~-) voltage is below 50VDC
Indoor (no corrosive gases, metallic dust)
-20 ℃ ~+60 ℃
90% Non-condensing
2
9.8m/S
(1G) under 20Hz
2
2m/S
(0.2G) at 20~50Hz
B-5
460V Series
4030
4045
30
45
40
60
15
18
660/690/720/760/800/830
±6V
400~800VDC
o
F)
IP50
VFD-F Series
4132
132
240
75
618/642/667/
690/725/750±6V
480~750VDC
IP10
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents