Communication Operation Command 1; Communication Frequency Setting; Communication Operation Command 2 - Delta Electronics AC Drive VFD-F Series User Manual

Vfd-f series
Table of Contents

Advertisement

VFD-F Series
09 - 06

Communication Operation Command 1

Settings
This parameter can be set by communication settings. It can't be set by keypad.
09 - 07

Communication Frequency Setting

Settings
This parameter can be set by communication settings. It can't be set by keypad.
09 - 08

Communication Operation Command 2

Settings
This parameter can be set by communication settings. It can't be set by keypad.
Bit0~1: 00: Disable
01: Stop
10: Start-up
11: JOG start-up
Bit2~3: Reserved
Bit4~5: 00: No function
01: FWD command
10: REV command
11: Direction change command
st
Bit6~7: 00: 1
step acce/decel speed
nd
01: 2
step acce/decel speed
rd
10: 3
step acce/decel speed
th
11: 4
step acce/decel speed
Bit8~11: 0000: Master speed
st
0001: 1
nd
0010: 2
rd
0011: 3
th
0100: 4
th
0101: 5
th
0110: 6
step speed
th
0111: 7
step speed
th
1000: 8
th
1001: 9
th
1010: 10
th
1011: 11
th
1100: 12
th
1101: 13
th
1110: 14
th
1111: 15
Bit12: Select Bit6~11 function
Bit13~15: Reserved
0~120.00Hz
Bit0: 1: EF ON
Bit1: 1: Reset
Bit2: 0: BB OFF, 1: BB ON
Bit3~15: Reserved
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
step speed
5-46
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Factory Setting: 00
Factory Setting: 60.00
Unit: 0.01
Factory Setting: 00

Hide quick links:

Advertisement

Table of Contents
loading