Specifications - Furuno IF-2550 Installation Manual

Table of Contents

Advertisement

FURUNO
SPECIFICATIONS OF INTERFACE UNIT
This equipment is used for distribution of navaids data from navigation equipment. Alarm signals
are also available to four outputs.
1
GENERAL
1.1
Distribution
Nav data (AD-10/NMEA) Input: 1 and Output: 4 (2 lines) or Input: 1 and Output: 8
Nav data (NMEA)
Mix distribution
1.2
Data conversion
NMEA0183/CIF
AD-10 to NMEA0183
NMEA reverse data (ferry mode)
1.3
Data sentences
<NMEA0183>
Input
Output
<CIF to NMEA>
Input (CIF)
Output (NMEA)
<NMEA to CIF>
Input (NMEA)
Output (CIF)
<Mix distribution>
I/O
1.4
Alarm function
Current signal
System failure
Data through
2
POWER SUPPLY
IF-2550
Input: 3 and Output: 8 (NMEA0183)
Three input sentences distributed to eight output max.
Convert from NMEA0183 to CIF, or from CIF to NMEA0183
AD-10 format to HDT or VHW sentence output
HCR, HDG, HDM, HDT, MWV, THS, VBW, VWR, VWT, GPatt
Ver 1.5/2.0/3.x/4.x, 4800/38400 bps
AAM, APA, APB, DBK, DBS, DBT, DPT, GGA, GLL, GSA, GSV,
HDG, HDT, MWV, RMA, RMB, RMC, THS, TLL, TTM, VBW, VHW,
VLW, VTG, ZDA, GPals, GPatt, GPxfr, IIalr, IIals, pireq, SDfnz,
SSevt
AAM, APA, APB, DBK, DBS, DBT, DPT, GGA, GLL, GSA, GSV,
HDG, HDT, MWV, RMA, RMB, RMC, THS, TLL, TTM, VBW, VHW,
VLW, VTG, ZDA, GPals, GPatt, GPxfr, IIalr, IIals, pireq, SDfnz,
SSevt
Ver 1.5/2.0, 2400/4800 bps to 4800 bps
11, 21, 22, 23, 24, 27, 28, 31, 32, 33, 34, 37, 38, 41, 43, 44, 47, 48,
57, 58, 66, 76, A1, D3
DBS, GLL, MTW, VCD, VWR, VWT, WPL, ZDA, SDfnz
Ver 1.5/2.0, 4800 bps
DBK, DBS, DBT, GLL, MTW, VHW, VTG, VWT, ZDA
11, 21, 22, 23, 24, 27, 28, 41, 43, 44, 47, 48, 58, 66, A1
Ver 1.5/2.0/3.x/4.x, or Ver 2.0 to Ver 1.5, 4800/38400 bps
Same as NMEA0183
Input: 1, output: 4 (current loop)
Detect data input error and output system failure
Status error, Remote acknowledge, Alarm output control
12-24 VDC: 0.1-0.05 A
SP - 1
IF-2550
E4482S02B