IN1 IN2 IN3
MD-550
(Setting:
ON)
-
3. Referring to the following figure and table, connect the cables to terminals TB1 through TB4.
TB4
TB1
TB3
TB2
TB 1
Terminal No.
IN 1 (DATA)
TB 1-1
TB 1-2
TB 1-3
IN 2 (SHIFT)
TB 1-4
TB 1-5
TB 1-6
IN 3
TB 1-7
TB 1-8
TB 1-9
OUT9
TB 1-10
TB 1-11
TB 1-12
TB 1-13
12-24 VDC
TB 1-14
TB 1-15
TB 1-16
TB 3
Terminal No.
OUT 5 (SHIFT) TB 3-1
TB 3-2
TB 3-3
OUT 6 (SHIFT) TB 3-4
TB 3-5
TB 3-6
Ports (〇: Available /-: Not Available)
OUT
OUT
OUT
1~4
5~8
9
-
-
-
-
How to connect wires to WAGO connector
Wire
Twist
Functions
RD1-H
RD1-C
FG/ISO_GND*
RD2-H
RD2-C
FG/ISO_GND*
RD3-H
RD3-C
FG/ISO_GND*
ALM-TD-A
ALM-TD-B
FG
N.C.
DC_IN (+)
N.C.
DC_IN (-)
Functions
TD5-A
TD5-B
FG
TD6-A
TD6-B
FG
ALARM
LOCAL_
REMOTE_
1~3
ACK
ACK/INV
-
-
-
-
Terminal
opener
Push
Push
Push
WAGO
connector
TB 2
Terminal No.
OUT 1 (DATA) TB 2-1
TB 2-2
TB 2-3
OUT 2 (DATA) TB 2-4
TB 2-5
TB 2-6
OUT 3 (DATA) TB 2-7
TB 2-8
TB 2-9
OUT 4 (DATA) TB 2-10
TB 2-11
TB 2-12
TB 4
Terminal No.
ALARM 1
TB 4-1
TB 4-2
TB 4-3
ALARM 2
TB 4-4
TB 4-5
TB 4-6
ALARM 3
TB 4-7
TB 4-8
TB 4-9
8
Remarks
One input, Four
outputs and Two
lines.
-
Data input / output
is as follows:
IN1→OUT1 to 4
IN2→OUT5 to 8
One input, Eight
-
outputs and
One line.
Procedure
1. Twist core.
2. Insert terminal opener and
push.
3. Insert wire into hole. Be
careful not to pinch the
sheath.
4. Release terminal opener.
5. Pull wire to confirm it is
correctly inserted.
Functions
TD1-A
TD1-B
FG/ISO_GND*
TD2-A
TD2-B
FG/ISO_GND*
TD3-A
TD3-B
FG/ISO_GND*
TD4-A
TD4-B
FG*
Functions
ALM1-H
ALM1-C
FG
ALM2-H
ALM2-C
FG
ALM3-H
ALM3-C
FG