7 Maintenance
Measuring principle
Measuring system
Measured variable
Measuring range
28
9.7

Software history

Software version / date
V 1.0 / 02.2001
V1.1 / 10.2001
10

Technical Data

10.1

Function and system design

Electronic monitoring and conversion of input signals in industrial temperature measurement.
The temperature head transmitter is a two wire transmitter with an analog output. It has measure-
ment input for resistance thermometers (RTD) in 2-, 3- or 4-wire connection, thermocouples and
voltage transmitters. Setup of the TMT 182 is done using the HART
module (DXR275, DXR375) or PC (COMMUWIN II or ReadWin
10.2

Input

Temperature (temperature linear transmission behavior), resistance and voltage
The transmitter monitors different measuring ranges depending on the sensor connection and input
signals.
Changes to software
Original software
Compatible with:
• HART ® Communicator DXR 275
(from OS 4.6) with DevRev 1,
DDRev 1
• Readwin ® 2000
• Commuwin II (version 2.07.01-2
and higher)
• AMS (version 5.X and higher)
• PDM (version 5.2 and higher)
New parameter (V2H1) for selection of
temperature compensation of the cold
junction when using customer specific
linearization of the TC polynom
Compatible with:
• HART ® Communicator DXR 275
with DevRev 2, DDRev 1
®
• Readwin
2000
• Commuwin II (version 2.07.01-4
and higher)
• AMS (version 5.X and higher)
• PDM (version 5.2 and higher)
TMT182
Changes to documentation
®
-Protocol with hand operating
®
2000 operating software).