Human Interface; 10.10 Certificates And Approvals - Endress+Hauser iTEMP HART TMT182 Operating Instructions Manual

Temperature head transmitter
Hide thumbs Also See for iTEMP HART TMT182:
Table of Contents

Advertisement

TMT182
Terminals
Display elements
Operating elements
Remote operation
CE-Mark
Hazardous area
approvals
GL
UL
CSA GP
Other standards and
guidelines
Endress+Hauser
• Cable up to max. 16 AWG (secure screws)
• or 16 AWG with wire end ferrules
• eyelets for easy connection of a HART
10.9

Human interface

No display elements are present directly on the temperature transmitter.
The measured value display can be called up using the ReadWin
ware.
No operating elements are present directly on the transmitter to prevent from manipulation. The
device parameters of the head transmitter are configured using the DXR275, DXR375 handheld ter-
minal or a PC with Commubox FXA191 and operating software (e.g. COMMUWIN II or
®
ReadWin
2000)
Configuration
Handheld terminal DXR275, DXR375 or PC with Commubox FXA191 and operating software
®
(ReadWin
2000 or COMMUWIN II).
Interface
PC interface RS232 and Commubox FXA191.
Configurable parameters
Sensor type and connection type, engineering units (°C/°F), measurement range, internal/external
cold junction, compensation of wire resistance with 2-wire connection, failure mode, output signal
(4 to 20/20 to 4 mA), digital filter (damping), offset, TAG + descriptor (8 + 16 characters), output
simulation, customer specific linearization, min./max. process value indicator function

10.10 Certificates and approvals

The measurement system fulfills the requirements demanded by the EU regulations. Endress+Hau-
ser acknowledges successful unit testing by adding the CE mark.
• FM IS, Class I, Div. 1+2, Group A, B, C, D / FM NI, Class I, Div. 2, Group A, B, C, D
• CSA IS, Class I, Div. 1+2, Group A, B, C, D
• ATEX II1G EEx ia IIC T4/T5/T6
• ATEX II3G EEx nA IIC T4/T5/T6
• ATEX II3D in compliance with EN 50281.1
Ship building approval (Germanischer Lloyd)
Recognized component to UL 3111-1
CSA General Purpose
• IEC 60529: Degrees of protection by housing (IP-Code)
• IEC 61010: Safety requirements for electrical measurement, control and laboratory instrumenta-
tion.
• IEC 61326: Electromagnetic compatibility (EMC requirements)
• NAMUR: Standardization association for measurement and control in chemical and pharmaceu-
tical industries. (www.namur.de)
• NEMA: Standardization association for the electrical industry
®
-handheld terminal with alligator clips
®
2000 or COMMUWIN II PC soft-
7 Maintenance
33

Advertisement

Table of Contents
loading

Table of Contents