Specifications of the VC-1801 Relay Module

Relays
Power supply
Enclosure
Ambient temperature range
Page 60 of 110
The relays are self-latching solid-state relays. Due to the
enclosure temperature, the error short-circuit current on each
relay output should not exceed 100 mA.
The relays are EMC-protected by means of TWS/transorbers,
which limit the maximum voltage to about 30 V DC.
Max. power consumption ................................... +24 V DC, ±5 %,
Total power loss ................................................................. 1.5 W
Short circuit of all relays ........................................................ 4 W
(please avoid this, it may be up to 10 W)
Material .............................................................................. PA66
Protection class............... ................................................... IP20
Dimensions (HxWxD).................. ........... .109x 22.5x114.5 mm
Working temperature range: ...................... -10 °C ≤ Ta ≤ +50 °C
Storage temperature range:........................ -40 °C ≤ Ta ≤ +85 °C
© Brüel & Kjær Vibro ● C106834.002 / V06
Technical alterations reserved!