5.1 Installation general

Installing the appliance.
1. Placing the appliance (§5.2
2. Connecting the condensate discharge (if applicable
3. Connecting the ducts (§5.6
4. Electric connection:
Connecting the power supply and, if applicable, a separate
ventilation switch (§5.11
Installation must take place under:
The safety regulations for central heating installations,

5.2 Placing the appliance

The following items should be observed when placing the Elan
appliance.
Place the appliance vibration-free and level.
Leave room between the appliance and the wall and the cei-
ling.
Put the appliance at an accessible place with su cient room
for service.
The installation room must be frost-free.
On a damp oor the air heater must be placed at a raised
level.
Put the appliance as closely as possible to the water input
output.

5.3 Conversion to Up ow version

A own ow Elan appliance can easily be converted to an Elan
Up ow appliance.
Open both lter doors
Unscrew 4 screws
(Torx T20 that hold the front panel
with the doors and take out this panel so the control panel
with the mounting bracket is accessible.
Unscrew the two screws (Torx T20 that hold the control
panel to the front panel and rotate this control panel 180
degrees.
10
.
4x Torx T20
2x Torx T20
Elan 10 2.0 / Elan 16 2.0 / Elan 25 2.1
uality requirements ventilation systems dwellings
The relevant articles in accordance with the Building ecree
Regulations for ventilation of dwellings and residential buil-
dings
The safety provisions for low voltage installations,
The regulations for connections to interior sewers in dwel-
lings and residential buildings
Any additional regulations of the local utilities
The Elan installation instructions
Put the appliance as centrally as possible relative to the air
ducts.
The installation room must be such that a good condensa-
te discharge with air trap and pitch for condensate can be
made (if applicable .
Make sure there is a free space of at least 1 m at the front of
the appliance and a free headroom of 1.8 m for cleaning the
lters and carrying out maintenance.
The air heater can be equipped with a free return. This me-
ans that the installation room has an open connection with
the rest of the dwelling.
Rotated the entire Elan appliance 180 degrees.
Remount the front panel with the doors with the four screws.
Use the two brackets to x the front panel.
The appliance is now an Up ow version.
614391-F