Mitsubishi Electric PQHY-P200YHM-A Data Book page 74

Table of Contents

Advertisement

Model
Power source
Cooling capacity
(
N
o
m
n i
a
) l
Power input
Current input
COP
Temp. range of
Indoor
cooling
Circulating water
Heating capacity
(Nominal)
Power input
Current input
C
O
P
Temp. range of
Indoor
heating
Circulating water
Indoor unit
Total capacity
connectable
Model / Quantity
Sound pressure level (measured in anechoic room)
High pressure
Refrigerant
piping diameter
Low pressure
Set Model
Model
Circulating
Water flow rate m
wate r
Pressure drop
Operating volume range
Compressor
Type x Quantity
Manufacture
Starting method
M
t o
r o
o
u
p t
C
a
s
e
h
e
t a
r e
Lubricant
External finish
External dimension HxWxD
Protection
High pressure protection
Inverter circuit (COMP.)
devices
Compressor
Type x original charge
Refri gerant
Control
N
t e
w
e
g i
t h
Heat exchanger
Water volume in plate
Water pressure Max.
HIC circuit (HIC: Heat Inter-Changer)
High pressure
Pipe between unit and
Low pressure
distributor
Drawing
External
Wiring
Document
Standard attachment
Accessory
Optional parts
●Turn DipSW 3-9 ON before power ON.
Remarks
●Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual.
●Due to continuing improvement, above specifications may be subject to change without notice.
●The ambient temperature of the heat source unit needs to be kept below 40 °C D.B.
●The ambient relative humidity of the heat source unit needs to be kept below 80%.
●The heat source unit should not be installed at outdoor.
●Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit.
●Be sure to provide interlocking for the unit operation and water circuit.
●The heat source twinning kit(low pressure) should be connected to the low pressure side of the heat source unit.
If the connected units are of different capacities, the heat source twinning kit(low pressure) should be installed in the unit with the largest capacity.
● Add brine to circulating water when a unit is operating at water temperature below 10°C.
● Twinning kit is required.
Notes:
1.<Standard CITY MULTI indoor unit>
Nominal cooling conditions(subject to JIS B8615-1)
Indoor:27°CDB/19°CWB(81°FDB/66°FWB)
Water temperature:30°C(86°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
2.<PWFY-P100/200VM-E-AU>
Nominal cooling conditions
Circulating water Temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 23°C, Water flow rate : 1.93m
Brine concentration 0%
3.<PWFY-P100VM-E-BU>
Nominal heating conditions
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 65°C, Water flow rate 2.15m
Brine concentration 0%
*1
kW
*1
c k
a
/ l
h
*1
BTU / h
kW
A
kW / kW
W.B.
°C
kW
*2
*2
kcal / h
*2 BTU / h
kW
A
kW / kW
D.B.
°C
dB <A>
mm(in.)
mm(in.)
PQRY-P300YHM-A(For Ground source)
3
/ h
L/min
cfm
kPa
3
m
/ h
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
t u
k
W
k
W
Acrylic painted steel plate
mm
1,160(1,100 without legs) x 880 x 550
45-11/16(43-5/16 without legs) x 34-11/16 x 21-11/16
in.
High pressure sensor, High pressure switch at 4.15MPa (601 psi)
Over-heat protection, Over-current protection
k
( g
b l
) s
l
MPa
mm(in.)
mm(in.)
3
3
/h (P100) / 3.86m
/h (P200)
3
/h
PQRY-P600YSHM-A(For Ground source)
3-phase 4-wire 380-400-415V 50/60Hz
69.0
59,300
235,400
15.62
26.3-25.0-24.1
4.41
15.0~24.0°C(59~75°F)
-5.0~45.0°C(23~113°F)
76.5
65,800
261,000
17.12
28.9-27.4-26.4
4
15.0~27.0°C(59~81°F)
-5.0~45.0°C(23~113°F)
50~150 % of heat source unit capacity
P15~P250 / 2~50 (Connectable branch pipe number is max. 48.)
28.58(1-1/8) Brazed
28.58(1-1/8) Brazed
5.76 + 5.76
3.4 + 3.4
17
4.5 + 4.5 ~ 7.2 + 7.2
Inverter
7
4 .
0
0 .
3
5
2 (
4
0
) V
M
E
L
3
2
Over-heat protection
R410A x 5.0kg (12lbs)
Indoor LEV and BC controller
181(400)
p
a l
e t
y t
p
e
5.0
1.0
-
19.05(3/4) Brazed
-
KB94T147
KE94C302
Installation Manual
Refrigerant conn. pipe
Heat Source Twinning kit: CMY-Q100VBK
Joint: CMY-Y102S-G2,CMY-Y102L-G2,CMY-Y202-G2,CMY-R160-J
Main BC controller: CMB-P108,1010,1013,1016V-GA
Sub BC controller: CMB-P104,108V-GB,CMB-P1016V-HB
Nominal heating conditions(subject to JIS B8615-1)
Indoor:20°CDB(68°FDB)
Water temperature:20°C(68°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
Nominal heating conditions
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 30°C, Water flow rate : 2.15m
Brine concentration 0%
- 70 -
4 .
6
53
PQRY-P300YHM-A(For Ground source)
96 + 96
17
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Inverter
7.4
0
0 .
3
5
2 (
4
0
V
M
E
L
3
2
Acrylic painted steel plate
1,160(1,100 without legs) x 880 x 550
45-11/16(43-5/16 without legs) x 34-11/16 x 21-11/16
High pressure sensor, High pressure switch at 4.15MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
R410A x 5.0kg (12lbs)
181(400)
p
a l
e t
y t
p
e
5.0
1.0
-
19.05(3/4) Brazed
22.2(7/8) Brazed
KE94C302
Unit converter
kcal
BTU/h
cfm
lb
3
3
/h (P100) / 4.30m
/h (P200)
*The specification data is
subject to rounding variation.
)
=kW x 860
=kW x 3,412
3
=m
/min x 35.31
=kg / 0.4536

Advertisement

Table of Contents
loading

Table of Contents