Pqhy-P-Y(S)Hm-A; Specification; Heat Source Units Specification For Standard Combination (Standard City Multi Indoor Units, Pwfy-P100/200Vm-E-Au) - Mitsubishi Electric PQHY-P200YHM-A Data Book

Table of Contents

Advertisement

2.PQHY-P-Y(S)HM-A

(1)

Specification

(1)-1 Heat source units specification for standard combination
(Standard CITY MULTI indoor units, PWFY-P100/200VM-E-AU)
Model
Power source
Cooling capacity
(
N
o
m
n i
a
) l
Power input
Current input
COP
Temp. range of
Indoor
cooling
Circulating water
Heating capacity
(Nominal)
Power input
Current input
C
O
P
Temp. range of
Indoor
heating
Circulating water
Indoor unit
Total capacity
connectable
Model / Quantity
Sound pressure level (measured in anechoic room)
R
e
r f
g i
e
a r
t n
Liquid pipe
piping diameter
Gas pipe
Circulating
Water flow rate m
water
Pressure drop kPa
Operating volume range
Compressor
Type x Quantity
Manufacture
Starting method
Motor output
Case heater
Lubricant
External finish
External dimension HxWxD
Protection
High pressure protection
d
e
v
c i
e
s
n I
v
e
t r
r e
i c
Compressor
Type x original charge
Refrigerant
Control
Net weight
Heat exchanger
Water volume in plate
Water pressure Max.
HIC circuit (HIC: Heat Inter-Changer)
Drawing
External
Wiring
Standard attachment
Document
Accessory
Optional parts
Remarks
●Turn DipSW 3-9 ON before power ON.
●Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be refer
●Due to continuing improvement, above specifications may be subject to change without notice.
●The ambient temperature of the heat source unit needs to be kept below 40 °C D.B.
●The ambient relative humidity of the heat source unit needs to be kept below 80%.
●The heat source unit should not be installed at outdoor.
●Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit.
●Be sure to provide interlocking for the unit operation and water circuit.
●Add brine to circulating water when a unit is operating at water temperature below 10°C.
Notes:
1.<Standard CITY MULTI indoor unit>
Nominal cooling conditions(subject to JIS B8615-1)
Indoor:27°CDB/19°CWB(81°FDB/66°FWB)
Water temperature:30°C(86°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
2.<PWFY-P100/200VM-E-AU>
Nominal cooling conditions
Circulating water Temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 23°C
3
Water flow rate : 1.93m
/h (P100) / 3.86m
Brine concentration 0%
kW
*1
*1
c k
a
/ l
h
*1 BTU / h
kW
A
kW / kW
W.B.
°C
kW
*2
*2
kcal / h
*2 BTU / h
kW
A
kW / kW
D.B.
°C
dB <A>
m
m
(
n i
) .
mm(in.)
3
/ h
L/min
cfm
3
m
/ h
kW
kW
mm
in.
c r
i u
( t
C
O
M
P
) .
kg(lbs)
l
MPa
Nominal heating conditions(subject to JIS B8615-1)
Indoor:20°CDB(68°FDB)
Water temperature:20°C(68°F)
Pipe length:7.5m(24-9/16ft.), Level difference:0m(0ft.)
Brine concentration 0%
Nominal heating conditions
Circulating water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp 30°C
3
Water flow rate : 2.15m
/h (P200)
Brine concentration 0%
PQHY-P200YHM-A(For Ground source)
3-phase 4-wire 380-400-415V 50/60Hz
22.4
19,300
76,400
3.92
6.6-6.2-6.0
5.71
15.0~24.0°C(59~75°F)
-5.0~45.0°C(23~113°F)
25.0
21,500
85,300
4.12
6.9-6.6-6.3
6
15.0~27.0°C(59~81°F)
-5.0~45.0°C(23~113°F)
50~130 % of heat source unit capacity
P15~P250 / 1~17
9.52(3/8) Brazed
19.05(3/4) Brazed
5.76
4.5 ~ 7.2
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Inverter
0.035(240 V)
MEL32
Acrylic painted steel plate
1,160(1,100 without legs) x 880 x 550
45-11/16(43-5/16 without legs) x 34-11/16 x 21-11/16
High pressure sensor, High pressure switch at 4.15MPa (601 psi)
O
v
r e
h -
e
t a
p
o r
e t
t c
o i
, n
Over-heat protection
R410A x 5.0kg (12lbs)
Indoor LEV and BC controller
195(430)
plate type
KB94T222
KE94C317
Installation Manual
Refrigerant conn. pipe
Joint: CMY-Y102S-G2
Header: CMY-Y104/108/1010-G
3
3
/h (P100) / 4.30m
- 5 -
0 .
6
47
96
3.4
17
4.6
O
v
r e
c -
r u
e r
t n
p
o r
e t
t c
o i
n
5.0
1.0
-
red to the Installation Manual.
Unit converter
kcal
=kW x 860
BTU/h
=kW x 3,412
cfm
=m
lb
=kg / 0.4536
*The specification data is
/h (P200)
subject to rounding variation.
3
/min x 35.31

Advertisement