Air-conditioners for building application heat source unit

Advertisement

Quick Links

Air-Conditioners For Building Application
HEAT SOURCE UNIT
PQRY-P200·250YGM-A
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.
For use with R410A

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PQRY-P200YGM-A

  • Page 1 Air-Conditioners For Building Application HEAT SOURCE UNIT PQRY-P200·250YGM-A For use with R410A INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.
  • Page 2 [Fig. 5.0.1] [Fig. 6.1.1] = < 40° = > = > A Heat source unit B 4-ø14 (Anchoring hole) C (Top view) [Fig. 6.1.2] [Fig. 7.1.1] Side piping D Anti-vibration pad etc. E Concrete base [Fig. 6.2.1] Top piping A Piping space (for side piping) B Heat source unit C Service space (front side) D (Top view)
  • Page 3 [Fig. 8.2.1] No.7 A : BC controller (standard) B : BC controller (main) No.1 No.1 No.2 No.2 C : BC controller (sub) D : indoor unit (20 ~ 140) No.3 No.4 No.3 No.4 E : indoor unit (200, 250) No.5 No.5 No.6 (mm)
  • Page 4 [Fig. 9.3.1] [Fig. 9.3.2] A : Nitrogen gas A : System analyzer B : To indoor unit B : Lo knob C : System analyzer C : Hi knob D : Lo knob D : Ball valve E : Hi knob E : Low press.
  • Page 5 10.3 [Fig. 10.3.1] <A> Change the jumper connector CN40 from CN41 to CN40 (51) (52) (01) (02) (55) (05) (06) <B> SW2-1:ON M1 M2 S M1 M2 S M1 M2 M1 M2 S M1 M2 S M1 M2 S M1 M2 S M1 M2 S <C>...
  • Page 6: Table Of Contents

    Contents 1. Safety precautions ..................6 8. Refrigerant piping installation ..............9 1.1. Before installation and electric work .......... 6 8.1. Caution ..................9 1.2. Precautions for devices that use R410A refrigerant ....6 8.2. Refrigerant piping system ............9 1.3.
  • Page 7: Before Getting Installed

    • Use liquid refrigerant to fill the system. • Install the power cable so that tension is not applied to the cable. - If gas refrigerant is used to seal the system, the composition of the refriger- - Tension may cause the cable to break and generate heat and cause a fire. ant in the cylinder will change and performance may drop.
  • Page 8: Confirmation Of Parts Attached

    4. Confirmation of parts attached 1 Connecting pipe × 1 (Connecting pipe is fixed with the unit.) Packing (inside ø23, outside ø35) × 1 3 Bushing × 2 5. Lifting method [Fig. 5.0.1] (P.2) Caution: Be very careful when carrying the product. - Do not have only one person to carry product if it is more than 20 kg.
  • Page 9: Pump Interlock

    2 Water quality standard 3 Please consult with a water quality control specialist about water quality control methods and water quality calculations before using anti-corrosive Lower mid-range Tendency solutions for water quality management. temperature water system 4 When replacing a previously installed air conditioning device (even when Recirculating Items Scale-...
  • Page 10: Additional Refrigerant Charge

    9. Additional refrigerant charge At the time of shipping, the heat source unit is charged with the refrigerant. As this 9.2. Precautions concerning piping connec- charge does not include the amount needed for extended piping, additional charg- tion and valve operation ing for each refrigerant line will be required on site.
  • Page 11: Airtight Test, Evacuation, And Refrigerant Charging

    Caution: G Service port [Use this port to evacuate the refrigerant piping and add an additional charge at • Always remove the connecting pipe from the ball valve and braze it out- the site. side the unit. Open and close the port using a double-ended wrench. - Brazing the connecting pipe while it is installed will heat the ball valve and Always reinstall the cap after operation is completed.
  • Page 12: Thermal Insulation Of Refrigerant Piping

    9.4. Thermal insulation of refrigerant piping Penetrations Be sure to give insulation work to refrigerant piping by covering high press. (liquid) [Fig. 9.4.4] (P.4) pipe and low press. (gas) pipe separately with enough thickness heat-resistant <A> Inner wall (concealed) <B> Outer wall polyethylene, so that no gap is observed in the joint between indoor unit and insu- <C>...
  • Page 13 2 Wiring examples • Controller name, symbol and allowable number of controllers. Name Symbol Allowable number of controllers Heat source unit controller BC Controller (main) One controller for one OC BC Controller (sub) Zero, one or two controllers for one OC Transmission booster unit Zero or one unit for one OC (*1) Indoor Unit Controller...
  • Page 14: Wiring Of Main Power Supply And Equipment Capacity

    10.4. Wiring of main power supply and equipment capacity Schematic Drawing of Wiring (Example) [Fig. 10.4.1] (P.5) A Switch (breakers for wiring and current leakage) B Heat source unit C BC controller (main) BC controller (sub) D Pull box E Indoor unit F Breakers for current leakage Thickness of wire for main power supply, On/Off capacities and system impedance Breaker for...
  • Page 15: Information On Rating Plate

    12. Information on rating plate Model P200 P250 Refrigerant (R410A) Allowable pressure (Ps) HP: 4.15 MPa, LP: 2.21 MPa Net weight MANUFACTURER: MITSUBISHI ELECTRIC CORPORATION AIR-CONDITIONING & REFRIGERATION SYSTEMS WORKS 5-66, TEBIRA, 6-CHOME, WAKAYAMA CITY, JAPAN...
  • Page 16 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.