Maintenance - Gerima SMA 30 BPV-25.L1 Operating Manual

Table of Contents

Advertisement

Maintenance

Repair must only be carried out by a
GERIMA trained technician!
Improperly repaired machines are
hazzard!
Increased risk of injury
Machine does not function correctly!
Hot carbide inserts and milling head!
Burn hazzard!
Wear protective gloves when replacing
the carbide inserts!
Maintenance plan:
Part to be serviced
Gear box
re-grease approx. every
Motor laminations
Height adjuster thread
Carbide inserts
Oil
Height adjuster thread:
Remove the screw for height clamping, lift the guiding
plate unit, clean the mounting thread, lubricate the
thread with.
©
Before servicing the
machine always must be
disconnected from the
compressed air supply
and secured against
reconnection.
Type of maintenance
work
certified GERIMA
1000 operating hours
service agent
peplace as
certified GERIMA
necessary
service agent
clean and lubricate as
trained technician disassemble guide
necessary
rotate or replace as
machine operator
necessary
put a drop oil in the
machine operator
nozzle, daily
Blunt tool can cause damage!
Service
Maintenance
procedure
disassemble
gear box
stave replace
plate unit
see page
15
see page
18
Oil:
Before connecting the machine to the compressed air line
put a drop oil in the nozzle, daily.
Maintenance
Blunt tool can overload the machine!
Inspect milling tools regulary for signs of
wear.
Wear protective gloves when changing
or readjusting the carbide inserts!
Materials
required
lubrication
0109.007.10-00002
greaset
stave-set
0109.113.09-00029
teflon pray
0109.007.10-00005
torx-key T15
spezial-
0109.007.10-00004
pneumatic-oil
Order-nr.
see page
15
18