Maintenance

Before serving the machine always
disconnect the machine from the
power supply by removing the
power cable from the socket !
Repair must only be carried out by
a GERIMA trained technician!
Improperly repaired machines are hazzard!
• Increased risk of injury
• Machine does not function correctly!
Hot carbide inserts and milling head!
• Burn hazzard!
• Wear protective gloves when replacing the
carbide inserts!
Maintenance plan:
Part to be serviced
Mitre gear
1
Ventilation slots
2
Carbon brushes
3
Height adjuster
4
thread
Carbide inserts
Service procedure 1:
Re-greasing / Caution!
The guarantee will be void if re-greasing is carried
out by anyone other than a certified GERIMA
service technician. Replenish with approx. 40 g of
the high-performance lubricating grease
0101.204.04-00018.
Service procedure 2:
To ensure that the machine can be cooled
properly, the ventilation slots must be kept clean.
To avoid damaging the motor windingd, it is
important that no foreign matter (e.g. chippings)
enter the motor compartment. Clean the motor
compartment regularly by blowing compressed air
through it.
Disposal of components removed from the machine
All machine parts and operating and auxiliary materials must be disposed of in accordance
with the applicable statutory provisions.
©
Type of mainte-
nance work
Re-grease every 250
Cerfied GERIMA
operating hours
service agent
Daily
Replace as necessary
technician
Clean and lubricate
as necessary
technician
Rotate or replace as
necessary
Blunt tool can cause damage!
• Blunt tool can overload the machine!
• Inspect milling tools regulary for
• Wear protective gloves when chan-
1
Service
Maintenance
procedure
Disassemble
gear head
Machine
Clean ventilation
operator
slots
Electrical
See page
19
Trained
Disassemble guide
plate
Machine
See page
13
operator
Service procedure 3:
For replacing brushes, open both covers (3), remo-
ve the old brushes and insert the new. Close the
opening with the covers.
Service procedure 4:
Unscrew and remove the guide plate, rotate and
remove the guide plate holder, clean the mounting
thread, lubricate the thread with teflon spray, then
reassemble
in reverse
order.
Maintenance
signs of wear.
ging or readjusting the carbide
inserts!
3
2
3
4
Materials
required
Lubrication
0101.204.04-00018
grease
Brush, cloth,
compressed air
Carbon brushes
0101.453.18-00001
(set)
Teflon spray
0000.064.15-00018
List of consumables
Order-nr.
from page 16
17