  • Page 2 Nucleus Freedom ® ™ Sound Processor Quick Reference Guide Coil Magnet Processing unit Indicator light Earhook BTE Controller Connection for accessories and monitor earphones Note: There is no accessory connection forwith the Mini BTE Controller.
  • Page 3: Changing The Program

    Parts of your speech processor Microphone ports Socket for coil Select button Display Increase and Decrease buttons On and off Press the Select button until you hear sound or see the symbols in the display. Changing the program Press the Select button repeatedly until you reach the program you want.
  • Page 4: Changing Batteries

    Changing microphone sensitivity Press the Increase or Decrease buttons until you reach the level you want. Changing batteries Remove the battery holder and replace the batteries.. Lock and unlock Press the Select button and the Decrease button to lock or unlock the processor.
  • Page 5 Using an accessory and/or the monitor earphones Plug in the monitor earphones Plug in the accessory Push the accessory into the monitor earphones To activate the accessory, push the Increase and Decrease buttons at the same time for at least one second. To select sound from the accessory, the in-built telecoil, or the microphone in turn, push the Increase and Decrease buttons at the same time for at least one second.
  • Page 6: Changing The Volume

    Using the in-built telecoil Push both the Increase and Decrease buttons until ‘T’ shows on the display. Changing the volume 1. Push either the Increase or Decrease buttons for more than one second, until you hear a beep and/or see a fl ashing ‘V’ on the display.
  • Page 7 Changing the microphone protector twist twist Slide your fi ngernail along the base to remove the cover. Replace the microphone protector so it fi ts securely. Put the cover back on. Check the cover every week and replace if dirty. Mic lock Attach the Mic lock as shown.
  • Page 9 Processing Unit and remove the battery holder from the Controller. Place all parts in your dry aid kit for at least twelve hours. If it then does not work, return it to your clinician. Cochlear cannot guarantee that they will be able to repair any water-damaged part. Program...
  • Page 10 Cochlear Benelux NV, Mechelen- Belgium, Tel: 32 15 36 2877 Fax: 32 15 36 2870 Cochlear France S.A.S., Saint Aubin- France, Tel: 33 811 111 993 Fax: 33 160 196 499 Cochlear Italia SRL, Bologna- Italy, Tel: 39 051 34 3578 Fax: 39 051 39 2062 Cochlear Nordic AB, Mölnlycke- Sweden, Tel: 46 31 335 1461 Fax: 46 31 335 1460...