1 — Installation of the UMAP 2110
1.5

Firmware Update

In CLI:
If you want to update firmware code, you must get image file from FTP Server.
Suppose that FTP Server IP address is 172.16.100.41 and the image filename is 'vmlinux_u2110_
0.05'.
Example:
1. Firmware update:
enable
configure
firmware login 172.16.100.41 username share password tg123
firmware upgrade vmlinux_u2110_0.73B05
(Firmware upgrade may take a few minutes, don't turn off or reset the system during the process.
You can get status using command 'show firmware status' in Enable execution mode.)
exit
show firmware status
(When status returns "Upgraded already!", you can restart the system to run new firmware
image. Once you upgrade successfully, you can't upgrade the second time unless you have
restarted the system.)
show firmware partition
Current Version:0.71B09
Partition
-------------------------------------------
1
2
(Note: the 'Active' status of the firmware partition information means the active partition for next
time restart, not current running partition. You can see which partition is current running partition
by referring to the Current Version. )
2. The UMAP 2110 provides two firmware memory partitions. If you want to change the firmware
partition for booting, use the following commands (if you change to the non-active partition, system
will restart immediately):
enable
configure
firmware partition <number>
32 / 54
//go to enable mode
//go to configuration mode
//back to enable mode
//show partition information
Version
Date
0.71B09
2007/07/05
0.73B05
2007/07/10
//go to enable mode
//go to configuration mode
//select partition 1 or 2 for next power-on
Status
--