Connecting Power

The RUGGEDCOM MX5000RE supports dual redundant AC and/or DC power modules
that can be installed in any combination.
The MX5000 is equipped with a screw-type terminal block, which provides power
to both power modules. The terminal block is installed using Philips screws and
compression plates, allowing either bare wire connections or crimped terminal lugs.
Use #6 size ring lugs for secure, reliable connections under severe shock or vibration.
For information about installing or removing a power module, refer to
Removing Power Supply Modules (Page
Electrocution hazard – risk of serious personal injury or death
The device may have two power modules equipped, which may be connected to
separate power sources. Make sure all power sources are off before servicing the
power module terminals.
RUGGEDCOM MX5000RE
Installation Manual, 01/2021, C79000-G8976-1060-13
Position the enclosure with the lifting ring facing up.
Screw
1
Figure 2.16
Mounting the RUGGEDCOM MX5000RE
WARNING
Crushing hazard – risk of serious injury or damage to equipment
Make sure the front panel is properly supported at all times. It is highly
recommended to employee the assistance of another technician.
Secure the RUGGEDCOM MX5000RE to a wall or mounting bracket using screws.
Torque each screw evenly to 61 N·m (45 lbf·ft) in a cross pattern.
DANGER
1
39)".
Installing the Device
2.15 Connecting Power
"Installing/
27