Installation

Important
If the oven is being installed into a built under oven housing unit ensure that the front rail at the top of the unit is not
installed as it could restrict ventilation.
Ensure that air can flow freely around the housing area. If the oven is being installed into a fully enclosed built-under
oven housing unit it may be necessary to cut a small slot in the top of the plinth fitted under the unit. Cut a section
400mm wide and a minimum of 15mm high to allow air to pass under the unit. Alternatively cut a section 400 x450mm
in the base of the carcass as indicated.
Failure to allow adequate ventilation to the appliance may result in overheating or damage to adjacent units and could
invalidate the warranty.
The walls of the kitchen units must be able to withstand temperatures of 75°C above ambient (typically this is between
90°C and 100°C). This appliance is type X installation.
When correctly installed ensure that there is a gap of 6mm minimum between the sides of the oven and adjacent
furniture doors.
Lift the oven carefully into position on the shelf, taking care NOT to lift it by the door handle. If you open the oven
door, you will see 2 screw holes, 1 on each side of the oven. The oven should then be secured to the housing by fitting
screws into these holes. Remember the housing should not be free standing but be secured to the wall and/or adjacent
fittings.
How to install your oven
You will need the following housing area fit your oven correctly.
Dimensions
Height (mm)
Width (mm)
Depth (mm)
The oven is designed to fit into a cabinet of 600mm width. The
oven can be built in or built under the kitchen units, but you must
ensure that it is properly ventilated. In the diagram the built-in
oven is ventilated by means of a space at the top of the kitchen
cabinet. There are many other methods of ventilating your oven -
Consult a qualified engineer for advice.
13
Oven
Housing
457
450
592
560
571
560 (min)
212
Statico Rev2 del 3/03
08-04-2005 10:05
Mueble y caracteristicas técnicas
457
Volumen útil del horno
fig. 14
52 lt
Características eléctricas
Pagina 85
48 lt
48 lt