Pentair CARBON FILTRATION SYSTEM 1.0 Installation And Service Manual page 16

Whole house carbon filtration systems
Hide thumbs Also See for CARBON FILTRATION SYSTEM 1.0:
Table of Contents

Advertisement

HOW TO PROGRAM THE END USER'S LEVEL
To begin, verify that the control is in the Service Mode.
Time of Day GL Remaining
Press the SCROLL BUTTON to advance to the next setting.
The following settings are available in the End User's Level:
1. TIME OF DAY
The control will display:
Set Time of Day
• Press the UP or DOWN ARROW to program the time of day.
Press the SCROLL BUTTON to advance to the next setting.
2. IMMEDIATE REGENERATION MODE
The control will display:
Regen in 10 sec
• If the control is left in this position, the timer will countdown from 10 to 0, initiating a regeneration at 0.
• To avoid an immediate regeneration, press the SCROLL BUTTON before the timer reaches 0.
Press the SCROLL BUTTON to advance to the next setting.
3. DELAYED REGENERATION MODE
The control will display:
Regen @ (1 am)
• If the control is left in this position, the unit will regenerate at the programmed time. The display will
remain in the Delayed Regeneration Mode until the regeneration has begun.
• To cancel the Delayed Regeneration Mode, press the SCROLL BUTTON.
16 • WHOLE HOUSE CARBON FILTRATION SYSTEM