7. Use
7.1
Working close to walls
To open and close the segment: switch off the
machine and pull the mains plug. The acces-
sory must be stationary.
Only raise the segment (13) when working
close to walls. Otherwise, the segment must
be lowered.
The open area of the safety guard must face the
direction of the wall.
7.2
Setting the speed
Set the optimum speed on the setting wheel (18),
depending on the application.
A wheel setting of between 4 and 6 is suitable for
most applications.
7.3
Switching On and Off
Always guide the machine with both hands.
Switch on first, then guide the accessory
towards the workpiece.
The machine must not be allowed to draw in
additional dust and shavings. When switching
the machine on and off, keep it away from dust
deposits. After switching off the machine, only set it
down when the motor has come to a standstill.
Avoid inadvertent starts: always switch the
tool off when the plug is removed from the
mains socket or if there has been a power cut.
In continuous operation, the machine
continues running if it is forced out of your
hands. Therefore, always hold the machine with
both hands using the handles provided, stand in a
safe position and concentrate on the work.
Machines with the designation W...RT:
Torque activation (with dead man's lever)
Switching on: Slide the trigger switch (16)
forwards and then push the trigger switch
(16) upwards.
Switching off: Release the trigger switch (16).
Machines with the designation W...RT:
Continuous operation (depending on features)
I
Switching on: Switch the machine on as described
above. Now slide the trigger switch (16)
forwards again and release in the front
8
16
I
0
16
0
position to lock the trigger switch (16)
(continuous operation).
Switching off: Push the trigger switch (16)
upwards and release.
8. Cleaning, Maintenance
Motor cleaning: The machine must be vacuumed
regularly, frequently and thoroughly through the
ventilation slots using a suitable vacuum cleaner.
The machine must be held firmly in this case.
Replacing the spring-mounted ring brush:
Replace worn brushes for optimal dust extraction.
Replacement brush set: Order No. 6.28214.

9. Troubleshooting

Machines with VTC and TC electronics:
The electronic signal display lights up
and the load speed decreases (not
W...RT). (17) There is too much load on the
machine! Run the machine in idling until the
electronics signal indicator switches off.
The machine does not start. The
electronic signal display (17) (depends
on model) flashes. The restart protection is
active. If the mains plug is inserted with the machine
switched on, or if the power supply is restored
following an interruption, the machine does not start
up. Switch the machine off and on again.
10. Accessories
Use only genuine Metabo accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating instruc-
tions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
11. Repairs
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
A defective mains cable must only be replaced with
a special, original mains cable from metabo, which
is available only from the Metabo service.
If you have Metabo electrical tools that require
repairs, please contact your Metabo service centre.
For addresses see www.metabo.com.
You can download spare parts lists from
www.metabo.com.

12. Environmental Protection

The sanding dust generated may contain
hazardous materials: do not dispose of this dust
with household waste, but at a special collection
point for hazardous waste.
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.