Writing Parameters Into Rom - Canon GALVANO GC-251 User Manual

Digital galvano scanner system
Table of Contents

Advertisement

8.4.

Writing Parameters into ROM

All parameters are written in the controller ROM. At activation, the parameters are automatically read
and set in the controller.
If parameters are modified, they should be written into ROM for activation with the same settings at the
next power-on.
Write modified parameters into ROM as follows:
GALILEO
・ Select the All Parameter tab. ①
・ Select an axis for parameter settings. ②
・ The current parameter values are displayed. ③
・ Press the Save to EEPROM button. ④
・ "Saving to EEPROM" is displayed. ⑤
Note: Some parameter settings may disable normal activation next time.
If this problem occurs, change the activation mode for no automatic homing to the origin and check the
set values. (See 6-1, "Setting Controller Activation Mode.")