Operation That Synchronizes With External Trigger Signal Input - Canon GALVANO GC-251 User Manual

Digital galvano scanner system
Table of Contents

Advertisement

6.2.
Operation that synchronizes with external trigger Signal input(Raster Scan)
"4-3. raster scan operation", It can be operated synchronizing with external trigger Signal.
【The Movement Pattern】
There are two kinds of movement patterns.
(The raster scan of one coming and going operates whenever the external trigger signal is input.)
Raster Scan position
(Current Angle Position)
External Trigger Signal
(The raster scan of one way operates whenever the external trigger signal is input.)
Raster Scan position
(Current Angle Position)
External Trigger Signal
① and ② operation pattern can be selected by RS-232C command (Command ID = 23 ' Operation
Mode setting ')
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
Angle
Voltage
Angle
Voltage
48