The external trigger signal is input from the digital I/O connector.
(See 5-1 'Connector Pin Arrangement)
Connector pin arrangement
Pin
Monitor Board
NO.
Signal Name
B5
Connection Specifications
3.3V TTL Input
FPGA
3.3V-TTL
【Operation procedure】
(Raster Scan Parameter Settings)
・Set Parameter ID =26
・Set Parameter ID =27
・Set Parameter ID =28
(Raster Scan Operation)
・Send Command ID=8
・Send Command ID=23 Data=8 (One way scan)
・Input the external trigger Signal
・Send Command ID=23 Data=0 Scan Stop
【Notes】
・ The external trigger input during raster scan move is ignored.
・ 10usec or less is uneven from the external trigger signal input at time until beginning to
・ actually operate.
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
I/O
Input
External Trigger Signal
D10
Raster Scan Time
Raster Scan Duty Ratio
Raster Scan Angle
Data=6 Movement Start (Movement to the Initial position
Data=9 (One coming and going)
(Reference: Data =3 in case of continuous operation)
Signal Description
R : 100Ω
of raster scan)
Logic
Remarks
High:ON
See Circuit below.
Connector
Select either
49