Download Print this page

LAVOR Pro TEKNA Series Instruction Manual page 17

Advertisement

Available languages

Available languages

EN
Repair
Check the level in the tank
and check whether the
rigid suction pipe is clean.
Replace the line filter.
Replace it.
Replace it.
Contact an authorised
service centre.
Check the positioning.
Replace it.
Poor boiler performance.
Boiler coil clogged with
limestone.
Repair
Clean burner nozzle filter.
Clean fuel filter.
Check diesel pump pres-
sure.
Descaling.
Combustion is not cor-
rect.
Impurities or water in the
fuel.
Repair
Clean fuel filter.
Clean the boiler.
Empty the tank and clean
it carefully.
Clean fuel filter as well.
tion
No detergent in the tank.
Incrusted injector.
Either coil or tube or lance
are clogged.
Repair
Fill the detergent tank.
Clean it.
Either cleaning or descal-
ing.
>
REPAIRS - SPARE PARTS
For any problems not mentioned in this manu-
al, or if the machine breaks down, you are urged
to contact an
for the relative repair or for any replacement of
components with original spare parts. Use ex-
clusively original replacement parts.
>
BOILER CLEANING
ATTENTION:
The boiler cleaning must be periodically ex-
ecuted every 180 ÷ 200 hours of working pro-
ceeding as follows:
Carefully remove the nozzle holder flange and
the electrodes holder (boiler head, ref. 13).
Clean with compressed air the nozzle filter and
check the electrodes position. (ref. 14).
Remove the boiler cap unscrewing the 3 nuts,
clean the deflector (ref. 15).
Manually take away the interior cap (ref. 16).
Unscrewing the locking nuts (ref. 17) and take
the boiler coil out.
-
Clean the coil by an iron brush (ref. 18).
Suck the residuums from the boiler (ref. 19).
Replace every parts doing the operations in the
inverse way.
-
.
-
-
23

Advertisement

loading