How To Collect Data At Certain Time Intervals [Interval Mode] - Kanomax Anemomaster 6162 Operation Manual

Hide thumbs Also See for Anemomaster 6162:
Table of Contents

Advertisement

3. Measurement Mode

3.2 How to Collect Data at Certain Time Intervals [Interval Mode]

[POINT 1]
DATA (1)
(2)
Data at each point is average value.
POINT 1 AVE 1= DATA(N)/N
POINT 2 AVE 1= DATA(N)/N
POINT N --- AVE H= DATA(N)/N
Display
(a)
<Measurement Setting
Screen>
www.lazodecontrol.com
DATA (1)
(3)
(N)
S-TIME (S)
Time interval until the next sampling starts
Interval Time --- INT (min)
Key
MENU
(1) Press MENU key.
,
(2) Select 2. MEASUREMENT.
SET
,
(3) Select 2. INTERVAL.
SET
(4) Set the measurement condition
,
SET
SET
[POINT 2]
(2)
(3)
(N)
DATA (1)
Time length required to measure at one point
How long it takes to finish measuring
Calculation Result
AVE=(AVE1+AVE2+ -----AVE N)/No. of POINT (N)
MAX=AVE I, MIN=AVE J
AVE1, AVE2,
AVE N are stored as a data at each point.
Procedure
Then press SET key.
Then press SET key.
in the same manner as when
configuring Average Mode
measurement (P14).
When the measurement condition is configured, select 7. SET
OK!, and press SET key.
+51 960 810 089
[POINT N]
(2)
(3)
(N)
S-TIME (S) × N (No. of Data)
INT (min) × No. of POINTS (N)
To select the item to be
changed
,
To change setting value
and YES/NO.
,
Setting is complete.
7. SET OK! SET
16
SET
SET
ventas@lazodecontrol.com

Advertisement

Table of Contents
loading

Table of Contents