Connecting The Solar Control Unit - Viessmann Vitocell 100-B Installation Instructions Manual

Table of Contents

Advertisement

Installing the cylinder temperature sensors
A
Fig. 14
Sensor well for cylinder temperature controller
A
Never wrap insulating tape around sensors.
Secure the cylinder temperature sensor to the out-
side of the contact spring of the sensor retainer (not
in the groove) so that it is flush with the front of the
spring.
Insert the sensor retainer together with the sensor
into sensor well
as far as it will go.
A

Connecting the solar control unit

Solar control unit:
Vitosolic 100, type SD1,
or
SDIO/SM1A electronics module
(cont.)
2.
1.
3.
4.
5.
The following cables/leads are already connected to
the Vitosolic 100 or the SDIO/SM1A electronics mod-
ule:
Cylinder temperature sensor
Pump connecting cable
On versions equipped with high efficiency circulation
pump: PWM cable, solar circuit pump
Note
If not yet connected, push the pump connecting cable
plug into the circulation pump.