Panasonic AW-E860N Operating Instructions Manual page 101

Convertible camera
Table of Contents

Advertisement

[ADJUSTMENT with RCU]
Use the horizontal phase control.
Horizontal phase
adjustment control
Subcarrier phase fine
adjustment control
Subcarrier phase coarse
adjustment switch
Remote control unit
Caution:
• When horizontal phase adjustment is required using RCU,
color bar/camera selector switch should be set to BAR.
Horizontal phase cannot be adjusted if the switch is in the
CAM position. After adjustment set color bar/camera
selector switch back to CAM.
• When horizontal phase adjustment is moved, color phase
is also moved. Adjust color phase whenever horizontal
phase adjustment is moved.
[ADJUSTMENT with ROP]
1. Select the first camera to be adjusted by
pressing the CAM CONTROL button.
2. Press the MENU button, and display the camera
setting menu on the LCD panel.
3. Turn the CONT dial, and display the G/L SETTING menu.
4. Push the CONT dial straight down, and display H PHASE
on the bottom line of the LCD.
5. Observe the waveforms of the genlock signal (black burst
signal or video signal (VBS)) and video signal output on
an oscilloscope, and adjust the CONT dial in such a way
that the horizontal phase is adjusted as shown in the
figure below.
Adjust the horizontal phase here.
6. Select the next camera by pressing the CAM CONTROL
button, and adjust the horizontal phase of the next
camera. Repeat this for all the connected cameras.
-29-
External sync (genlock)
signal input (black burst
signal)
Video signal output