  • Page 1 Programmable Terminal NA Series Practice Guide IAG Collection for EtherNet/IP™ Monitor NA5-15□101□ NA5-12□101□ V454-E1-01...
  • Page 2 This guide describes reference information to create and use IAG objects. It does not provide safety information. Be sure to obtain the manuals for NA Series Programmable Terminal, read and understand the safety points and other information required for use, and test sufficiently before actual use of the...
  • Page 3: Terms And Conditions Agreements

     Note about Descriptions Rating and performance is tested separately. Combined conditions are not warranted. - Reference data is intended to be used just for reference. Omron does NOT guarantee that the Omron Product can work properly in the range of reference data.
  • Page 4 - Omron products are designed and manufactured as commodity for general industrial products. For this reason, the usages (a) to (d) are to be unintended. Omron makes no guarantees on Omron products, if you use Omron products for those purposes.
  • Page 5 The warranty described in this Terms and Conditions Agreements is a whole and sole liability for Omron products. There are no other warranties, expressed or implied. Omron and its distributors are not liable for any damages arisen from or relating to Omron products.
  • Page 6: Table Of Contents

    Table of Contents Terms and Conditions Agreements ............3 Table of Contents ..................6 Related Manuals ................7 Precautions ..................8 Overview.................... 9 Overview ..................9 System Configuration ..............10 Library Versions ................11 IAG Descriptions ................12 EtherNet/IP NetworkMonitor ............12 DLR Monitor ..................
  • Page 7: Related Manuals

    Related Manuals Model Title V117 NA5-15W□□□□ Programmable Terminal NA Series Hardware NA5-12W□□□□ USER’S MANUAL NA5-9W□□□□ NA5-7W□□□□ V118 NA5-15W□□□□ Programmable Terminal NA Series Software NA5-12W□□□□ USER’S MANUAL NA5-9W□□□□ NA5-7W□□□□ V119 NA5-15W□□□□ Programmable Terminal NA Series Device NA5-12W□□□□ Connection USER'S MANUAL NA5-9W□□□□...
  • Page 8: Precautions

    OMRON. (5) The information in this guide is current as of February 2020. It is subject to change without notice because of product’s update.
  • Page 9: Overview

    Overview 3-1 Overview This document describes IAG collections that directly read the information about the EtherNet/IP network or devices connected with the NA Series HMI. • IAG external specifications • IAG installation on a screen Icon Description EtherNet_IP_NetworkMonitor Monitor for an EtherNet/IP device on a...
  • Page 10: System Configuration

    3-2 System Configuration The IAG objects were tested with the system configuration and versions below. NA Series Sysmac Studio projects with IAGs EtherNet/IP Screen Transfer PC (Sysmac Studio) CIP Safety on EtherNet/IP devices ■Controller NX-CSG320 NX102 Series Series Series ■Ring Super Visor...
  • Page 11: Library Versions

    Library Versions This chapter describes the versions of the IAG library. You must check versions of the items listed in the table below before using the library. Item Description How to Check the Version IAG Collection The distributed IAG collection has The version can be checked in the library versions.
  • Page 12: Iag Descriptions

    IAG Descriptions 5-1 EtherNet/IP NetworkMonitor 5-1-1 Specifications  External Specifications Object EtherNet_IP_NetworkMonitor Category EtherNet_IP_Monitor ・ Detects all the EtherNet/IP devices that connected with the same network as NA’s Ethernet Functions Port1/Port2. And displays the models and IP addresses on the EtherNet/IP Screen. ・...
  • Page 13 Screen Specifications  EtherNet/IP EtherNet/IP devices that connected to NA’s Ethernet ports are detected and displayed on this screen. Screen User I/F Specifications Part Description Group The information of a device is shown. Refer to No. 9 and later for details. You can select an NA port.
  • Page 14 Events are executed according to the unit type. Button When an error occurs on GS-S Unit, outlined in red. Lamp Layout Properties Default Description Position Set in Property. (Left, Up) Size Set in Property. (Width, Height) Filtering You can filter the devices to display on the EtherNet/IP screen. Window Filtering setting is possible using the I/O variable FilterMode.
  • Page 15 You are required to enter a password in this window when registering a network configuration. Network Following to the security settings of NA, register a network configuration when a login is permitted. Configuration If a user name is not assigned to the input variable RegisteredUserName, a configuration is registered without Registration displaying this window.
  • Page 16 Network Differences between the current network configuration and the registered configuration are displayed. Configuration Mismatches Window User I/F Specifications Part Description Differences between the current network configuration and the registered Data Display configuration are displayed. Data Lamp Configurations are compared based on unit model and IP address. Data Display A number of mismatches is displayed.
  • Page 17 (1 to kMonitor0 127) Type Object type. Not changeable. EtheNet_IPMonitor_ IAG_12inch.EtherNe t_IP_NetworkMonito Version IAG version 1.0.0.0 Publisher IAG publisher Omron Promotion Sample Appearance Background Color Background color of a page Item Color pallet Transparent selection Character Direct input string Layout ▼Position (Left , Top)
  • Page 18 Image 1: Transparent 2: The origin of coordinates locates at the top left corner of NA screen. Precautions for Correct Use In the usage described in this document, do not set the In/Out variables CurrentPageName and ExitMonitor and leave them blank to avoid unintended behaviors.
  • Page 19  Events & Actions The following IAG event can be detected. Event Description SelectETAP Executed when an ETAP device is selected. SelectGI_S Executed when a GI-Series Unit is selected. SelectNXR_ILM Executed when an NXR- ILM Unit is selected.  Animations Basic motions can be defined.
  • Page 20 5-1-2 Installation to Screen  Property Assignment This IAG reads and displays the configuration information of an EtherNet/IP device that connected to NA’s Ethernet port. Assign a variable to the following property (Input/ Output) in order to share the IP address information of the EtherNet/IP device pressed on the screen with each device’s detailed information page.
  • Page 21: Dlr Monitor

    5-2 DLR Monitor 5-2-1 Specifications  External Specifications Object DLR_Monitor Category EtherNet_IP_Monitor ・ Monitors and displays a disconnection in the DLR topology and a failure in the ring node Functions during the Ring Topology Screen is displayed. ・ Executes an event that the GI-S Unit or the GI-ILM Unit button is pressed to be selected in the Ring Node displayed on the Ring Topology screen.
  • Page 22  Screen Specifications Ring Topology This screen shows a ring topology of the DLR. Screen User I/F Specifications Part Description Button Reads out the configuration Data Display Information about DLR Super Visor is shown. Data Display & The information of the selected device is shown. Button Executes the event SelectGI_S when the GI-Series Unit’s button is touched.
  • Page 23 Communication This pop-up window notifies that communications between NA and DLR Super Visor were failed. Error Window User I/F Specifications Part Description Button Executes the event SelectEIPMonitor. Layout Properties Default Description Position Fixed (Left, Up) Size Fixed (Width, Height)
  • Page 24 This pop-up window notifies that DLR Super Visor failed to create a DLR table. Configuration The error occurs when the ring has been broken at creating a table. List Error Window User I/F Specifications Part Description Data Display IP address of a disconnected point is displayed. Button Executes the event SelectEIPMonitor.
  • Page 25 Over-connected This window notifies that the number of devices connected to the DLR has exceeded the limit. Window It appears when 50 and more devices are connected, including DLR Super Visor. User I/F Specifications Part Description Data Display The number of devices connected to the DLR is displayed. Button Executes the event SelectEIPMonitor.
  • Page 26 (1 to 127) Type Object type. Not changeable. EtherNet_IP_Monito r_IAG_12inch.DLR_ Monitor Version IAG version 1.0.0.0 Publisher IAG publisher Omron Promotion Sample Appearance Background Color Background color of a page Item Color pallet Transparent selection Character Direct input string Layout ▼Position (Left , Top)
  • Page 27 Precautions for Correct Use In the usage described in this document, do not set the In/Out variables CurrentPageName, PreviousPageName and ExitMonitor and leave them blank to avoid unintended behaviors.  Version History IAG version Description IAG collection version 1.0.0.0 First edition Ver1.00 ...
  • Page 28 5-2-2 Installation to Screen This IAG Collection assumes the following usage.  When the button for the ETAP device on the DLR SuperVisor, which is displayed by the IAG “EtherNet_IP_Network Monitor” located on another page, is pressed, the screen switches to the page with this IAG and then this IAG accesses to the device to receive and display the necessary information.
  • Page 29  Events and Actions settings for IAG “DLR Monitor” Set the action “ShowPage” for the IAG event “SelectEIPMonitor.” Event Description SelectEIPMonitor Executed when the EIP Monitor button is pressed. Enter the name of the page where the IAG “ETtherNet_IP_Networ kMonior” is placed. When the event that the DLR Super Visor device is selected and its button is pressed in the IAG EtherNet_IP_Network Monitor, the...
  • Page 30: Revision History

    Revision History Revision Code Date Revision Description February 2020 First edition...