Installation Manual for the
1500
Automatic Gate Operator
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so GTO, Inc. shall in no event be liable for direct,
indirect, incidental, special or consequential damages or loss of profits whether
based in contract tort or any other legal theory during the course of the warranty
or at any time thereafter. The installer and/or user agree to assume responsibility
for all liability and use of this product releasing GTO, Inc. from any and all
liability. If you are not in agreement with this disclaimer or do not feel capable
of properly following all installation and safety instructions you may return this
product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before
attempting to install and use this automatic gate operator. This gate operator
produces a high level of force. Stay clear of the unit while it is operating and
exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only and
should never be used by pedestrians.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety,
as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912
or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950
www.gtopro.com
2005 GTO, Inc.
©

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SW-1500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GTO SW-1500

  • Page 1 You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter.
  • Page 2 Please record the product serial number (located on the rear of operator arm), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate operator. Serial Number ____________________ Date of Purchase ____________________ Remember to keep all receipts for proof of purchase.
  • Page 3: Table Of Contents

    Table of Contents Gate Operator Class Categories------------------------------------------------------------inside cover Units and Standards Conversion Chart ---------------------------------------------------inside cover PLEASE READ THIS FIRST! -------------------------------------------------- Important Safety Instructions -------------------------------------------------- Disconnecting the Operator -----------------------------------------------------------page 1 Important Safety Instructions for the Consumer------------------------------------page 2 Secondary Means of Protection Against Entrapment ------------------------------page 5 Required Safety Precautions for Gates-----------------------------------------------page 6 Warning Signs and Labels -------------------------------------------------------------page 7 Installation --------------------------------------------------------------------------...
  • Page 4: Please Read This First

    The gate must not exceed 8 feet and 550 pounds or exceed 16 feet and 150 pounds (please see Technical Specifications on page 10). The GTO/PRO® SW-1500 Automatic Gate Operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind.
  • Page 5: Important Safety Instructions

    Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.
  • Page 6: Important Safety Instructions For The Consumer

    IMPORTANT SAFETY INSTRUCTIONS For The Consumer WARNING: To reduce the risk of injury or death: READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS Entrapment Zones for a proper Pull-To-Open installation: Zone 1 – leading edge of the gate and the fence post. Zone 2 – between the gate and the gate post. Zone 3 – the path of the gate. Zone 4 –...
  • Page 8 If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with an activated gate when it is moving or stationary.
  • Page 9: Secondary Means Of Protection Against Entrapment

    The GTO/PRO® Automatic Gate Operator utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the GTO/PRO® has provisions for the connection of Type B2 protection to be used as the secondary type of entrapment protection, if desired.
  • Page 10: Required Safety Precautions For Gates

    Pedestrian Gate Entrapment Protection GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.
  • Page 11: Warning Signs And Labels

    Logo and warning labels (2) installed on each side of operator housing These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements. GTO DC SW1500 Series Conforms to UL325...
  • Page 12: Installation

    Do not allow children to operate gate or play in gate area. This gate is for vehicles only. Pedestrians must use a separate entrance. Warning Signs (2) GTO Transmitter(1) Gate Operator (1) Post Pivot Bracket (1) Post Bracket (2) Hardware Bag Contents Receiver (1) 10’...
  • Page 13 • If your gate is more than 1000' away from an AC power source you will need to use at least one GTO/PRO® 5 watt Solar Panel (FM122) to charge the 12 Volt automotive or marine type battery (not included). See the Accessory Catalog.
  • Page 14: Technical Specifications

    • The system is powered by a 12 Vdc automotive or marine battery. • Battery charge is maintained by a 120 Vac, 18 Vac output transformer [rectified to 14.5 Vdc (40 VA) through the GTO control board] or by optional GTO Solar Panels [the panel should generate minimum of 5 W at 300 mA]. A diode on the control board prevents battery discharge.
  • Page 15: Installation Overview

    Installation Overview Pull-to-Open Gates (Gate Opens into the Property) The diagram shown below is an example of a pull-to-open installation on a chain link fence and single gate. Mounting the operator on a masonry column requires special procedures; see Column Installation Information on page 36 if you intend to mount the operator on a column.
  • Page 16: Installation Of The Mounting Hardware

    Installation of Mounting Hardware The position of the post bracket determines the leverage and efficiency of the operator. The post bracket position also sets the clearance between the operator and gate in the open and closed positions (minimum 2 inches for safety reasons). The curved design of the post bracket works well for installations on round and square fence posts.
  • Page 17 Determining the Mounting Position of the Post Bracket Assembly and the Gate Bracket Step 3 Insert the " x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a " lock washer, "...
  • Page 18 for minimum 2 inches of clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
  • Page 19 Installing the Post Bracket Assembly and Gate Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post bracket assembly and gate bracket. After marking your reference points, remove the operator and brackets from the fence and gate.
  • Page 20: Mounting The Operator

    firmly holds the gate in the closed position using the positive stop plate. The positive stop helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO/PRO® Automatic Gate Lock (see Accessory Catalog). Step 12 Remove hairpin, clevis pin, and washer from front mount and close the gate (remember to support operator).
  • Page 21 At this stage of the installation, the operator should be installed on the gate and the closed position stop should be in place. Check List • The gate is plumb, level, and swings smoothly on its hinges. • A plate or support was added for the gate bracket (if necessary). •...
  • Page 22: Powering The System

    Powering the System IMPORTANT: GTO/PRO SW 1500 • The battery. The battery must be placed inside a weatherproof case and located within 6 feet of the operator arm. The 10 foot harness supplied connects the battery to the operator arm.
  • Page 23: Connecting The Battery

    Connecting the Battery Step 1 With the opener mounted in the upside down position remove the Control Board Access Panel on the bottom of the opener arm. Battery Harness Connector BLACK to NEGATIVE RED to POSITIVE Step 4 IMPORTANT: Make sure the power switch on the opener arm is in the OFF position.
  • Page 24: Detailed Wire Routing Diagram

    See the illustrations to the right and below. If you have any questions please call GTO Technical Service at 1-800-543-1236. Battery Harness Connectors...
  • Page 25: Connecting The Transformer

    22. IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.
  • Page 26 Strip " off the ends of the low voltage wire and twist tightly. Insert these ends to the 18 VAC terminal block located on the control board (see illustration at right). The wires can be inserted into either terminal regardless of color. Be certain not to let the exposed wires touch each other! Tighten set screws against exposed end of wires.
  • Page 27: Connecting Solar Panel(S)

    This DIP selects the mode of operation of the "AUX OUT" terminal. The OFF (factory) setting is selected when the GTO/ PRO Automatic Gate Lock is used with the connected to the "AUX OUT (+)" terminal and the BLACK wire from the lock control board is connected to the "AUX OUT (–)"...
  • Page 28: Setting The Closed Position

    Turn the power switch on arm to the ON position operator Your GTO/PRO SW-1500 has two Limit Settings 1) OPEN Limit setting: (Gate in the OPEN POSITION / FACTORY SET & NOT ADJUSTABLE) The open limit setting is the fully open position.
  • Page 29: Obstuction Sensitivity And Auto-Close

    Obstruction Sensitivity Potentiometer Setting IMPORTANT: For safety reasons the obstruction setting or Stall Force on the GTO/PRO SW 1500 the factory set at MIN (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates.
  • Page 30: Setting Your Personal Transmitter Code

    Setting Your Personal Transmitter Code All GTO transmitters are set to a standard code at the factory and are ready to operate your your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code.
  • Page 31: Installing The Receiver

    • Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the GTO Sales Department). NEVER splice receiver cable! • Run the cable through PVC conduit to protect it from damage.
  • Page 32: Connecting Additional Safety Devices

    Connecting Additional Safety Devices Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with any applicable UL standards (Underwriters Laboratories) and national and regional safety codes.
  • Page 33 PLEASE NOTE: Non-contact sensors are not included with the GTO/PRO SW-1500. The GTO/PRO SW-1500 can also accept "Safety" input from normally open "dry-contact" output devices such as photo beams connected to the SAFETY input terminal. Any safety device that pulls more than 40 mA DC must have its own power supply.
  • Page 34: Connecting Accessories

    CLOSE GTO/PRO Automatic Gate Lock unlocks and locks automatically as gates open and close. Used with the GTO/PRO® The Automatic Gate Lock system for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft.
  • Page 35 Connect a wire from the V+ terminal on the LOOP Controller to the AUX OUT (+) terminal on the GTO/PRO SW 1500 control board. Connect a wire from the NO (Normally Open) terminal on the LOOP controller to the EXIT terminal on the GTO/PRO SW-1500 control board.
  • Page 36 The Driveway Wand Sensor is designed for residential and agricultural applications and is compatible with GTO/PRO® automatic gate operators. The Wand Sensor is an electromagnetic sensor, which offers 'hands free' operation of the GTO/PRO® Gate Operator with a 12 ft. radius of detection of vehicles in motion.
  • Page 37: Push To Open Installation

    Push to Open Installation Determining The Mounting Position of The Post Bracket Assembly Swinging gates shall not open into public access areas! A "Push-to-Open" gate opens out from the property. A Push-to-Open Bracket is required for this type of installation (see Accessory Catalog).
  • Page 38: Setting The Open Position Limit

    Step 3 With the gate in the fully closed position and the operator retracted, swing the operator to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The operator must be level. (Some vertical adjustment is possible by sliding the post bracket assembly up and down.) Drill gate bracket to cross member using (2) 3/8"...
  • Page 39 Step 3 With the gate in the desired open position PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds. Step 4 Press the transmitter button and allow the gate to return to the closed position. YOUR GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED.
  • Page 40: Maintenance & Troubleshooting Guide

    The alarm will beep for 1 second upon power up. Visual/LEDs Feedback RF LED (LED2): Blinking when a 318 MHz signal is received. This LED is typically off when the receiver is connected and no 318 MHz signal is presented. the GTO Service Department.
  • Page 41 STATUS LED (LED1): While the unit is IDLE: 1 blink with 2 seconds off: Free Exit terminal is shorted to common. 2 blink with 2 seconds off: Safety terminal is shorted to common. 3 blink with 2 seconds off: Edge terminal is shorted to common. 4 blink with 2 seconds off: Cycle terminal is shorted to common.
  • Page 42: Repair Service

    1. First use the procedures found in the Maintenance & Troubleshooting Guide (see page 36). 2. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the back of opener arm) and date of purchase when calling for assistance.
  • Page 43: Column Installation Information

    Column Installation Information F THIS OPERATOR WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS: READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING The simplest solution is to install the operator in a push-to-open configuration (requires Push-To-Open Bracket, see Accessory Catalog).
  • Page 44: Accessory Catalog

    OLAR ANEL The Solar Panel (FM123) is a 10 watt solar powered battery charger for use with the all GTO/PRO DC gate operator systems. Particularly suited for remote installations, each Solar Panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire).
  • Page 45 If you have a question about GTO/PRO accessories The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright GTO®, GTO/PRO®, Bulldog®...

Table of Contents