Download Print this page
HIKVISION HF-VS409 Manual
HIKVISION HF-VS409 Manual

HIKVISION HF-VS409 Manual

Visual smoke detection camera
Hide thumbs Also See for HF-VS409:

Advertisement

Quick Links

HF-VS409
Visual Smoke Detection Camera
UD24995B
E N G L I S H
Diagram References
Appearance
1
1
2
3
microSD Card Slot
RESET Button
TEST/SILENCE Button
5
Indicator
6
TAMPER
Note: The appearance of the device vary according to different model. Refers to the actual device.
Wiring Description
2
Refers to the figure for the details of the terminal.
1. Pull out the green connector inside the Alarm In/Out Interface.
2. Loosen the screws with a mini slotted screwdriver, put in the cable and tighten the screws.
3. Plug the connector into the green base.
Installation
3
Before you begin:
1. Accessories that you need to prepare for installation: Junction box (Optional).
2. If the mounting location (such as the ceiling) is longer than 10 meters, multiple detectors
need to be installed.
3. The installation parameters should be subject to EN14604 Code for Design of Automatic
Fire Alarm System".
4. Avoid installing the detector in the following locations:
-Kitchens, hot water heaters, bathrooms and other high-humidity spaces.
-Air conditioners, fans, heating outlets, and strong convection locations.
-Places that are dusty, dirty, or frequented by insects.
-High temperature and easily polluted places such as stoves.
-Where the object is obscured.
-Places within 1.5 meters of the light.
-The upper part of the spire house, the corner of the room and other closed spaces.
3.1
Mounting Location
Note: The requirement of the mounting location is shown as the figure.
3.2
Ceiling Mounting
Ceiling Mounting without Junction Box
1.
Drill 4 screw holes on the ceiling according to the mounting template.
2.
Insert the plastic expansion sleeves into the screw holes, and fix the mounting base with screws.
3.
Smooth the cables and turn the smoke detector clockwise until it snaps in place.
Ceiling Mounting with Junction Box
1.
Drill 4 screw holes on the ceiling according to the mounting template.
2.
Insert the plastic expansion sleeves into the screw holes, and fix the junction box with screws.
3. Fix the mounting base to the junction box with screws.
3.
Smooth the cables and turn the smoke detector clockwise until it snaps in place.
Configuration
4
Network Settings
1
Connect your device to Ethernet, and you can configure parameters of the device via browser.
Activation
2
You should activate the device before the first login.
Default IP Address: 192.168.1.64
Activation via SADP tool, the client software and the web browser are supported. Refers to the
User Manual for details.Here takes activation via web browser for example.
1. Connect the device to your computer with network cable. Make sure the device IP address and
the computer's should be in the same IP segment.
2. Power on the device.
3. Enter the device IP address in the address bar of the web browser, and press Enter to create
admin account. Click OK to activate the device.
Configuration and Operation via Web
3
Enter the device IP address in the address bar of the web browser to login.
You can configure and operate the device. Scan the QR code for details.
4
Local Settings
Smoke/Temperature Alarm
In standby mode, when smoke particles or the temperature reach the settings, the alarm will be
triggered.
The buzzer will beep and the indicator keeps red.
You can enable the function via web to upload the alarm records, smoke concentration and
pollution data to platforms and FTP. Scan the QR Code to see the User Manual for details.
TEST
Make sure the buzzer and indicator work properly.
In standby mode, press the
TEST/SILENCE
button, and the device will enter test mode. After
testing, the device will exit the test mode automatically.
Test Mode: The buzzer beeps for 10 times, and the indicator keeps red.
Mute
In alarm mode, hold the
TEST/SILENCE
button to mute the alarm (the mute period is 10 minutes).
Mute Mode: The buzzer stops beeping, and the indicator keeps red.
Mute Period: After the alarm is mute, if the smoke concentration or the temperature still reach
the settings, the alarm will be triggered in 10 minutes.
Reset
When the alarm is in mute mode(when the red light keeps red and the buzzer stops beeping),
press the
TEST/SILENCE
button again to reset the device.
In alarm mode, if the smoke dissipates or the temperature declines, the alarm will automatically
resume to standby mode.
Default Setting
Hold the RESET button and power on the alarm. Hold the button for 10 to 15 seconds while the
device is powered on. Release the button and the device will be restored to default settings.
1
2
4
Camera
1
3
4
6
3.1
19.69''(500 mm)
Refers to Smoke Detected Camera User
Manual (scan the QR code) for details.
Pull out the plug
5
Indicator
Buzzer
Flashing Green every 90 s
Disable
Bolid Red
Squeal
Flashing Red every 40 s
Beeping Once every 40 s
Quick Flashing Green 3 times
Disable
Flashing Yellow every 40 s
Beeping for every 40 s
Flashing Red every 100 s
Disable
3.2
Minimum distance
from the side wall
2
Illustration
Alarm Input
Alarm Output
Device
Device
Status
Standby Mode
Smoke/Temperature Alarm
Low Voltage
Tampering Alarm
Maze Pollution
Temperature Sensor Fault
Mounting Template
Plastic Expansion Sleeves
Mounting Base
Screws
Smoke Detector
Alarm In/Out Interface
Network
Interface
Power Interface
Mounting Template
Plastic Expansion Sleeves
Junction Box
Screws
Mounting Base
Screws
Smoke Detector

Advertisement

loading
Need help?

Need help?

Do you have a question about the HF-VS409 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION HF-VS409

  • Page 1 HF-VS409 Visual Smoke Detection Camera UD24995B E N G L I S H Alarm In/Out Interface Illustration Diagram References Appearance Network Interface microSD Card Slot RESET Button TEST/SILENCE Button Camera Indicator TAMPER Note: The appearance of the device vary according to different model. Refers to the actual device.
  • Page 2 EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF...