"Detector" diagnosis module can display the gray level data curve of the sensor array and you can
press "Start Emit" and "Stop Emit" to observe the gray level of the curve so as to check whether
the detector is in good condition and whether the position of the detector board is in the appropriate
postition.
a. When you click the "Start Emi" button, the X-ray begins to emit and the curve rises; when you
click the "Stop Emi" button, the X-ray stops emitting, the curve falls back.
b. Click the "Forward", "Stop" and "Backward" button to realize the "Forward", "Stop" and
"Reverse" operations of the conveyor.
c. Click the "View-1/6" as the main perspective curve diagnosis interface, click the "View-2/7" as
the side perspective curve diagnosis interface.
d. Click the "OFF" button to get the system to exit from the equipment diagnosis menu.
The standard reference curve is as shown in Fig 6.25a or Fig 6.25b:
Fig 6.25a Detector Diagnosis Interface (Single Perspective)
Fig 6.25b Detector Diagnosis Interface (Double Perspectives)
Curve Judgement Criterion:
a. The different devices are equipped with different number of the detection plates and the number
of sensing points differs.
- 35 -
Chapter 6 Menu Operation