Advertisement

Quick Links

DS-K3Y501 Flap Barrier
Quick Start Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-K3Y501 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION DS-K3Y501

  • Page 1 DS-K3Y501 Flap Barrier Quick Start Guide...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3Y501 Flap Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3Y501 Flap Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3Y501 Flap Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death.
  • Page 7 DS-K3Y501 Flap Barrier Quick Start Guide Cautions: • Stainless steel may be corroded in some circumstances. You need to clean and care the device by using the stainless steel cleaner. It is suggested to clean the device every month. • Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
  • Page 8 DS-K3Y501 Flap Barrier Quick Start Guide Available Models Product Name Model Description Flap Barrier DS-K3Y501-L1 Left Pedestal 1 DS-K3Y501-L2 Left Pedestal 2 DS-K3Y501-M1 Middle Pedestal 1 DS-K3Y501-M2 Middle Pedestal 2 DS-K3Y501-R Right Pedestal You can follow the picture below to select pedestals: Scan the QR code to get User Manual of Flap Barrier.
  • Page 9 DS-K3Y501 Flap Barrier Quick Start Guide viii...
  • Page 10: Table Of Contents

    DS-K3Y501 Flap Barrier Quick Start Guide Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................1 Chapter 2 Wiring ........................3 2.1 Components Introduction ...................... 3 2.2 Wiring Electric Supply ......................4 2.3 Wire Interconnecting Cable ....................5 2.3.1 General Wiring ......................
  • Page 11 DS-K3Y501 Flap Barrier Quick Start Guide 4.3 Switch to RS-485/RS-232 Mode ................... 25 4.4 Switch Relay Output Mode (NO/NC) ..................25 4.4.1 Barrier Control Relay Output Mode ................25 4.4.2 Alarm Relay Output Mode (NO/NC) ................26 Chapter 5 Activation ......................... 27 5.1 Activate via SADP .........................
  • Page 12: Chapter 1 Overview

    DS-K3Y501 Flap Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction Figure 1-1 Appearance The flap barrier designed to detect unauthorized entrance or exit. By adopting the flap barrier integratedly with the access control system, person should authenticate to pass through the lane via presenting IC or ID card, scanning QR code, etc.
  • Page 13 DS-K3Y501 Flap Barrier Quick Start Guide • Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation • Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing duration •...
  • Page 14: Chapter 2 Wiring

    DS-K3Y501 Flap Barrier Quick Start Guide Chapter 2 Wiring 2.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system’s power supply.
  • Page 15: Wiring Electric Supply

    DS-K3Y501 Flap Barrier Quick Start Guide Figure 2-2 Components 2 Note • If the turnstile contains two lanes, standing at the entrance position, the IR boards on the left pedestal are the IR sending boards. The IR boards on the right pedestal are the IR receiving boards.
  • Page 16: Wire Interconnecting Cable

    DS-K3Y501 Flap Barrier Quick Start Guide Note • The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, ware an insulation cap at the end of the bare cable.
  • Page 17: Wire Face Recognition Terminal

    DS-K3Y501 Flap Barrier Quick Start Guide Figure 2-4 Wire General Device Note • The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique supports or sales and purchase for 5.5 m interconnecting cables.
  • Page 18: Terminal Description

    DS-K3Y501 Flap Barrier Quick Start Guide Figure 2-5 Face Recognition Terminal Wiring Note • The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique supports or sales and purchase 5.5 m interconnecting cables.
  • Page 19: Master Control Board Terminal Description

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.1 Master Control Board Terminal Description The master lane control board contains power supply interface, battery interface, motor drive interface, strip light interface, motor encoder interface, door open position detection interface (reserved), debug port, lane communication interface, interconnecting interface, and DIP switch.
  • Page 20: Main Control Board Terminal Description

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.3 Main Control Board Terminal Description Figure 2-8 Main Control Board Table 2-1 Main Control Board Terminal Description Main Control Board Terminal Description Power Output 1 +12 V Power Output Grounding Wiegand Card Indicator of Card Reader Control Output (Invalid Card...
  • Page 21 DS-K3Y501 Flap Barrier Quick Start Guide Main Control Board Terminal Description Grounding RS-485 Interface Grounding RS-485 B- Connect to Card Reader RS485- RS-485 B+ Connect to Card Reader RS485+ Grounding RS-485 C- Connect to Card Reader RS485- RS-485 C+ Connect to Card Reader RS485+...
  • Page 22 DS-K3Y501 Flap Barrier Quick Start Guide Main Control Board Terminal Description Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) COM1 NO/NC2 Alarm Output Relay 2 (Dry Contact) COM2 NO/NC3 Alarm Output Relay 3 (Dry Contact) COM3 NO/NC4 Alarm Output Relay 4 (Dry Contact)
  • Page 23: Main Control Board Serial Port Id Description

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.4 Main Control Board Serial Port ID Description You can use the jumper cap on the main control board to switch the interface communication mode. For details about switching between RS-232 and RS-485 communication type, see Switching RS-485/RS-232 Mode.
  • Page 24 Use the jumper cap to switch the serial port communication mode with the lane controller. By default, the interface is wired and it is in RS-485 communication mode. If wiring other controllers (compatible with Hikvision communication protocol), use the jumper cap to switch between RS-485 and RS-232 communication mode.
  • Page 25: Rs-485 Wiring

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.5 RS-485 Wiring Note • There are four RS-485 interfaces, which are for connecting ID card reader, IC card reader, QR code scanner, fingerprint and card reader, card recycler, text screen, fingerprint reader, and face recognition terminal.
  • Page 26: Rs-232 Wiring

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.6 RS-232 Wiring Note • There are three RS-232 interfaces (UART4, UART7, and UART8). UART7 and UART8 can connect QR code scanner, card recycler, and text screen, while UART4 can connect QR code scanner, card recycler, text screen, and face recognition terminal.
  • Page 27: Wiegand Wiring

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.7 Wiegand Wiring Note Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand card reader. 2.4.8 Barrier Control Wiring By default, the barrier has connected with the main control board. The lane control board can control the barrier status.
  • Page 28 DS-K3Y501 Flap Barrier Quick Start Guide Entering Wiring Exiting Wiring...
  • Page 29: Alarm Output Wiring

    DS-K3Y501 Flap Barrier Quick Start Guide 2.4.9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .
  • Page 30: Chapter 3 Installation

    DS-K3Y501 Flap Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes. Figure 3-1 Lock Holes 3.2 Install Lithium Battery The lithium battery supplies power for master lane control board and slave lane control board when the device is powered off.
  • Page 31: Install Pedestals

    DS-K3Y501 Flap Barrier Quick Start Guide • Refers to Components Introduction to view the lithium battery's position. • The working temperature of the lithium battery is 0 °C to 45 °C. 1. Remove the screws on the battery component to disassemble the battery component.
  • Page 32 DS-K3Y501 Flap Barrier Quick Start Guide Figure 3-3 Dimension 1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Draw a central line on the installation surface of the left or right pedestal. 3. Draw other parallel lines for installing the other pedestals.
  • Page 33 DS-K3Y501 Flap Barrier Quick Start Guide Note For detailed information about burying and wiring interconnecting cables, see Wire Interconnecting Cable . 6. Seal the bottom of the turnstile to avoid water from entering. 7. According to the entrance and exit marks on the pedestals, move the pedestals to the corresponded positions.
  • Page 34: Chapter 4 Device Settings

    DS-K3Y501 Flap Barrier Quick Start Guide Chapter 4 Device Settings After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode,...
  • Page 35: Initialize Device

    DS-K3Y501 Flap Barrier Quick Start Guide The keyfob's indicator of the will flash twice if the pairing is completed. 5. Set the DIP switch as OFF, and reboot the turnstile to take effect. Note • You can also pair the keyfob via the client software. For details, see Managing Keyfob in User Manual of iVMS-4200 AC Client Software.
  • Page 36: Switch To Rs-485/Rs-232 Mode

    DS-K3Y501 Flap Barrier Quick Start Guide 4.3 Switch to RS-485/RS-232 Mode Take the UART2 and UART3 on the main control board as an example. If the Jumper cap's position is like the picture displayed below. (The black part is the jumper cap.) The serial port is in RS-485 communication mode.
  • Page 37: Alarm Relay Output Mode (No/Nc)

    DS-K3Y501 Flap Barrier Quick Start Guide The jumper cap's position of barrier opening for exit (NO) is as below: The jumper cap's position of barrier closing for entrance (NC) is as below: The jumper cap's position of barrier closing for exit (NC) is as below: 4.4.2 Alarm Relay Output Mode (NO/NC)
  • Page 38: Chapter 5 Activation

    • Get the SADP software from the supplied disk or the official website http:// www.hikvision.com/en/ , and install the SADP according to the prompts. • The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 39: Activate Device Via Client Software

    DS-K3Y501 Flap Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 40 DS-K3Y501 Flap Barrier Quick Start Guide three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product.
  • Page 41: Appendix A. Tips For Scanning Fingerprint

    DS-K3Y501 Flap Barrier Quick Start Guide Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
  • Page 42 DS-K3Y501 Flap Barrier Quick Start Guide Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another...
  • Page 43: Appendix B. Dip Switch

    DS-K3Y501 Flap Barrier Quick Start Guide Appendix B. DIP Switch B.1 DIP Switch Description The DIP switch is on the master lane control board. No.1 to No 8 is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
  • Page 44 DS-K3Y501 Flap Barrier Quick Start Guide Device Mode Function Decimal Value Binary Value Controlled 0010 Entrance and Free Exit Free Bi-​ d irection 0011 Free Entrance and 0100 Controlled Exit Free Entrance and 0101 Prohibit Exit Prohibited Bi- 0110 direction...
  • Page 45: Appendix C. Event And Alarm Type

    DS-K3Y501 Flap Barrier Quick Start Guide Appendix C. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None...
  • Page 46: Appendix D. Table Of Audio Index Related Content

    DS-K3Y501 Flap Barrier Quick Start Guide Appendix D. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions.
  • Page 47 UD16204B-A...

Table of Contents