Installation
Installation
Installation
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.
Location
Location
Location
When selecting the location for the equipment, keep
the following in mind:
• There must be sufficient space on all sides of
the equipment for installation, operator access,
maintenance, and air circulation.
• Ensure that the mounting surface and mounting
hardware are strong enough to support the weight
of the equipment, fluid, hoses, and stress caused
during operation.
• There must be a start/stop control (C) within easy
reach of the equipment. See Typical Installation,
Fig. 1.
3A3384B
All manuals and user guides at all-guides.com
Mount the
the Pump
Pump
Mount
Mount
the
Pump
See
Mounting Hole Patterns, page
Stand Mount
Stand
Stand
Mount
Mount
1. Secure the stand to the floor with M19 (5/8 in.)
bolts. Use bolts that engage at least 152 mm (6
in.) into the concrete floor to prevent the pump
from tipping.
2. Level the pump as required, using shims.
Wall Mount
Mount
Wall
Wall
Mount
1. Drill four 7/16 in. (11 mm) holes using the
bracket as a template. Use any of the three
mounting hole groupings in the bracket. See
Mounting Hole Patterns, page
2. Bolt the bracket securely to the wall using bolts
and washers designed to hold in the wall's
construction.
3. Attach the pump assembly to the mounting
bracket.
Installation
26.
26.
7