1. Mount the display into the sign structure using the provided holes in
the mounting flange. Alternate holes can be drilled into the mouting
flange if needed. Refer to Figure 1 and Figure 2.
Note: Do not drill holes into the display face. This will void the
warranty.
2. Use appropriate screws or other hardware to secure the sign to the
structure.
Note: The display is front ventilated. Do not block the display face.
This may void the display warranty.
Grounding
FL-3000 and FL-4500 series displays do not require a local earth ground
electrode.
The displays still require a safety ground from the electrical service panel
for the primary power wires to comply with national electric codes.
Power Installation
Install Daktronics Fuelight
The ground from the circuit must be connected to the ground bus bar
or green wire attached to the
grounding stud within each Fuelight
display. Refer to Figure 3. Do not
connect neutral to ground at the
disconnect or at the display, this
would violate electrical codes
and void the warranty. Use a
disconnect so that all ungrounded
conductors can be disconnected.
To connect power to the display:
1. Route the power cable into
the display through one of
the knockouts on the display's
backsheet.
2. Use wire nuts or other
appropriate hardware to
connect power wires - hot
(black) and neutral (white) - to
the power supply harness or
pigtail. Refer to Figure 3 and
Figure 4.
DD2238842
Rev 08
06 February 2019
displays using a two wire plus ground circuit.
TM
TOP
TOP
TOP
TOP
TOP
TOP
Power
Box
Figure 3: Proper Grounding for Multiple Fuelight Displays
201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766
Figure 1: Securing Digit Cabinet
Figure 2: Inserting Digits into
Cabinet
Display 1
Power In
From Power
Box At
Display Base
Power Out
From Display 1
Daisy Chained
To Display 2
Display 2
TOP
TOP
TOP
TOP
Power Out
From Display 1
Daisy Chained
TOP
TOP
To Display 2
Display 3
Page 1 of 4
daktronics
Use Grounding
Stud
Use Grounding
Stud
Use Grounding
Stud

Advertisement

loading

Summary of Contents for Daktronics Fuelight FL-3000

  • Page 1 The displays still require a safety ground from the electrical service panel for the primary power wires to comply with national electric codes. Power Installation Install Daktronics Fuelight displays using a two wire plus ground circuit. Figure 2: Inserting Digits into...
  • Page 2 5/16” nut driver. Refer Figure 6: Line-to-Line Cable to Figure 8. Figure 7: Installed Line-to-Line Figure 8: Installed Drain Wire Cable with Drain Wire DD2238842 201 Daktronics Drive Rev 08 Brookings, SD 57006-5128 06 February 2019 www.daktronics.com/support 800.325.8766...
  • Page 3 Pull excess cable into the display cabinet, coil cable, zip tie it together and carefully place coil • inside the display cabinet. For additional support information or communications installation information, visit www.daktronics.com/ support. Installing a Cash/Credit Display A rectangular opening must be provided to accommodate the Cash/ Credit™...
  • Page 4 The displays still require a safety ground from the electrical service panel for the primary power wires to comply with national electric codes. Cash/Credit Display Power Installation Install Daktronics Cash/Credit displays using a two-wire plus ground circuit. The ground from the circuit must be connected to the grounding stud within each Cash/Credit display. Do not connect neutral to ground at the disconnect or at the display, this would violate electrical codes and void the warranty.

This manual is also suitable for:

Fuelight fl-4500