Page 1
Petroleum Price Displays DF-2009/2109 Series (36", 48", and 60" digits) Installation and Operation Manual ED-18514 Rev 0-2 July 2007 201 Daktronics Dr. PO Box 5128 Brookings SD 57006 Tel: 866-343-3122 605-697-4300 Fax: 605-697-4444 Hwww.daktronics.comH email: helpdesk@daktronics.com...
Page 2
– without written permission of the publisher. ™ ® DataMaster and DataTime are trademarks of Daktronics, Inc. Other trademarks used in this manual are the property of their respective owners.
Page 3
Reproduction Reference ED-18514 – P1356 DF-2009/2109 Series Displays 1. This page is for reproduction reference only and will not be included in the manual. 2. This manual is to be copied on FRONT AND BACK PAGES –8 ½ x 11 paper. The first and second pages, Cover Page and Copyright Page, are blank on back.
Replacing a Digit Segment for 36" Digits ..............18 Replacing a Digit Pixel for 48" and 60" Digits ............19 Replacing a Breakout Board ..................19 Daktronics Exchange and Repair & Return Programs ............ 20 Exchange Program ......................20 Repair & Return Program ..................... 21...
Page 6
Section 6: DM-100 Controller ..................... 23 DM-100 Overview ......................... 23 Replacement Parts List ....................23 Connecting the DM-100 to the Display ................24 DataMaster Insert and Code ....................25 Petroleum Price Display Operation ..................25 Petroleum Price Display Startup ................. 26 Petroleum Price Controller Operation ................
Page 7
Figure 1: DF-2009 ..............................1 Figure 2: DF-2109 with Top Caption ........................ 1 Figure 3: DF-2109 with Caption and Cash/Credit Option ................1 Figure 4: Daktronics Drawing Label ........................ 2 Figure 5: Display Identification Label ......................2 Figure 6: Lifting the Display ..........................4 Figure 7: Location of Mounting Clips ......................
This manual explains the installation, maintenance, and operation of Daktronics DataMaster 2009 and DF-2109 Outdoor LED Petroleum Price Displays. If questions arise regarding the installation, operation, or service of these systems, contact Daktronics Customer Service at the contact numbers listed on the cover page of this manual.
Drawing A-244838. Figure 4: Daktronics Drawing Label The serial and model numbers of a Daktronics display can be found on the ID label. In theses models, the ID label is located near the power termination block behind the center digit. The label will be similar to the one shown in Figure 5.
Disconnect power when servicing the display. • Do not modify the display structure or attach any panels or coverings without the written consent of Daktronics. Reference Drawings: Display Mounting, Clip Angles to Structure ........... Drawing A-320125 Shop Drawings for specific display type & size ............Appendix A Shop Drawings The table below gives the number of the Shop Drawing for each display model.
Actual site demands will dictate the appropriate mounting method. Daktronics strongly recommends using a spreader or lifting bar to lift the display. Using a spreader bar ensures that the force on the eyebolts is straight up, minimizing lifting stress.
National Electric Code may be used. • Resistance to ground 10 ohms or less: This is required by Daktronics for proper display performance. If the resistance to ground is higher than 10 ohms, it will be necessary to install additional grounding electrodes to reduce the resistance.
Power Disconnect The National Electrical Code requires the use of a lockable power disconnect within sight of or at the display. Follow these guidelines for correct connection: • Connect the grounding electrode cable at the local disconnect, never at the display driver/power enclosure.
Signal Connection To connect signal, it is necessary to access the driver inside the display cabinet. The driver is attached to a small panel between the left and center digits (Figure 11). Open the small panel by turning the latch access fasteners counterclockwise. Figure 11: Location of Signal Driver LED Drivers In the display, the LED driver performs the task of...
Signal Wiring Signal wires are terminated with a telephone-type RJ14 connectors. Route the cable from the jack in the J-box to J6 on the host driver (Figure 12). Run another RJ14 connector from J8 (Output) to the next (client) display, connecting at J6 (Input). Follow this sequence to all displays in the sign network.
Allow only qualified service personnel access to internal display electronics. Disconnect power when not using the display. Daktronics displays are built for long life and require little maintenance. However, at times, displays may not work correctly. Use this section to define the problems and find solutions.
Driver LEDs The driver inside the display contains three LEDs that provide information about the working of the display. Refer to Figure 15 for their location. These LEDs can help pinpoint problems with driver set-up or operation. The LEDs give the following information: Color Status Green...
Troubleshooting This section lists potential problems with the display, indicates possible causes, and suggests corrective action. This list does not include every possible problem, but it does represent some of the more common situations that may occur. (Refer to the appropriate manual for a list of potential problems with add-on or separately mounted message centers.
Section 5: Parts Replacement Daktronics Petroleum Price Displays are built for long life and easy maintenance. On occasion, however, a part may need to be replaced. In that case, follow these steps. 1. Find the part number label on a part or refer to the list in Section 5.1 for the correct part number.
Page 24
Daktronics Part Description Communication Boards and Accessories Modem, RS232 coated, internal, 0P-1279-0003 J-box, signal converter, w/modem 0A-1279-0162 J-box, signal converter, radio 0A-1279-0161 RJ11 to RJ45, M-M, straight, 18” cable 0A-1137-0300 Server Radio, outdoor 0A-1146-0079 Client Radio, w/Quick Connect 0A-1146-0078 Cable, 6-cond., 18 AWG, j-box to Server Radio...
Instructions for Replacing Parts Component Locations and Access Review Figure 16 to find the location of the latch access fasteners and the components that may need replacing. Larger digit panels will have three latch fasteners on a panel. Figure 16: Locations of Internal Components Replacing a Driver To replace a driver, follow these steps: 1.
Replacing a Surge Board The surge board is mounted inside the display below the driver. To replace the surge board, follow these steps: 1. Open the small panel by turning the latch fasteners a half-turn counterclockwise. 2. Disconnect and label all wires and connectors on the surge board –...
Replacing a Digit Pixel for 48" and 60" Digits To remove a digit pixel, follow these steps: 1. Open the specific digit panel by turning the latch access fasteners counterclockwise. 2. Disconnect both of the 2-pin power/signal connectors from the back of the individual pixel, noting where they are connected (Figure 20).
DataMaster Serial No. _______________________________ Exchange Program Daktronics unique Exchange Program is a quick service for replacing key parts in need of repair. If a part requires repair or replacement, Daktronics sends the customer a replacement, and the customer sends the defective part to Daktronics. This decreases display downtime.
Repair & Return Program For items not subject to exchange, Daktronics offers a Repair & Return Program. To send a part for repair, follow these steps: 1. Call or fax Daktronics Customer Service: Phone: 866-343-3122 Fax: 605-697-4444 2. Receive a Return Materials Authorization (RMA) number before shipping.
Refer to Drawing B-256001 for information on possible control options and connection procedures. Note: When the carrier delivers this Daktronics order, open the packages and inspect for shipping damage such as rattles and dents. See that all equipment is included as shown on the packing slip.
Connecting the DM-100 to the Display The DataMaster displays may be controlled from a location inside a building or from the base of the display, depending on customer preference. Drawing B-256001 and the subsections that follow provide greater detail on both installations using signal wire. Wire Control from the Base of the Sign This outdoor control option (Figure 23) permits operation of the sign from the base of the display.
DataMaster Insert and Code The DM-100 uses a keypad insert to program rate information into Daktronics LED DataMaster Rate Displays. The DM-100 insert illustrated in Figure 25 is used to control the displays. If an insert is lost or damaged, make a copy of the insert from Drawing A-167856 located in Appendix A.
Petroleum Price Display Startup To operate the DataMaster Petroleum Price displays, the DM-100 must first be programmed to the gas price function. Use the [Set Function] key on start-up. Use the following table as a guide to start-up procedures. LCD Screen Action Plug the wall pack transformer into a 120 V AC CURRENT...
Petroleum Price Controller Operation The Petroleum Price Controller LCD display will default to showing the current display settings on power up. The following text will be shown on the LCD. LCD Screen Action The display will toggle between these two LINE PRICE screens.
Menu Items Pressing the [Menu] key accesses the following settings: Setting Price Line 1 Price Line 2 Price Line 3 Price Line 4 Price Line 5 LED Test? Display Option Modem Settings Display Status Set Time 12HR Use Menu items 1-5 to edit the price on each line of the display. Lines are typically numbered top to bottom with 1 being the top of the display.
Display Status The Display Status menu item can be used with a bi-directional display setup to get display status back from the driver. The controller will cycle through various LCD message screens, illustrated below and on the following page, that show display status. Press [Clear] at any time to exit the Display Status submenu.
Set Time This allows the time and date to be set with the DM-100. LCD Screen Action HH – Current hours value SET TIME–12HR MM – Current minutes value HH:MM AM ↓ AM – Current AM/PM setting (not shown when 24-hour time is selected) Using the number keys, enter the Time in the 12-hour (or 24-hour) format.
Dimming The dimming level of the Rate display can be adjusted in two ways. A light sensor, mounted on each driver, can detect the level of ambient light at the display location and dim the sign's LEDs accordingly. This function is known as automatic dimming. When the manual dimming function is selected, the LEDs remain at the same level of brightness regardless of the level of light detected at the display.
The following LCD prompt is shown for either Manual or Automatic dimming selections: LCD Screen Action ↑ ↓ Press the up or down arrow key < > to INTENSITY XX ↓↑ modify the current intensity of the display ENTER TO SET (Note: The DataMaster must be connected to the display) XX –...
Section 7: RC-50 Controller The RC-50 controller can be configured to program petroleum price variances displayed on the LED DataMaster Petroleum Price sign. The instructions provided in this section discuss the functions used by the operator to control the Petroleum Price display. Reference Drawing: RC-50 Quick install Guide ................
Section 8: RC-100 Controller The RC-100 controller can be configured to program petroleum price variances displayed on the LED DataMaster Petroleum Price sign. The instructions provided in this section discuss the functions used by the operator to control the Petroleum Price display. Note: Although multiple wireless handheld controllers may be connected to a single wireless base station server, the rate display application allows for only one handheld device to be connected at a time.
• This message appears next on the screen. CHANGE FUNCTION? • If “GAS PRICE” was shown on the bottom line PRESS SET of the LCD during startup, do nothing. The FUNCT controller will automatically default to previous Gas Price settings. •...
Modifying Price Line Settings The petroleum price can be modified either by pressing the [Edit] key during operation (previous section) or using the [Menu] key (see Menu Items). Refer to the following key to identify the item to be edited. L = Current line number to be edited D.CC = Current dollars and cents value to edit T = Current tenths of cent value to edit...
Dimming The dimming level of the rate display can be adjusted in two ways. A temperature/light sensor mounted near the display can detect the level of ambient light at the display location and dim the sign's LEDs accordingly. This function is known as automatic dimming. When the manual dimming function is selected, the LEDs remain at the same level of brightness regardless of the level of light detected at the display.
Page 47
• Press [Enter] to accept this option. DIMMING BLANK SIGN ↓ • BLANK THE The next LCD dialog will ask whether to blank the screen or escape. The LCD SIGN? toggles between Yes and No. Pressing <ENT> YES [Clear] resumes normal operation; pressing <CLR>...
Section 9: POS Interface Installation and Operation A Point of Sale (POS) interface option is available with DataMaster LED Petroleum Price Displays. Displays with this option automatically update when product prices are changed in the POS. Displays with the POS interface option will be supplied with a POS Interface Kit (see table below for part numbers).
8. Plug the transformer (T-1118) into an outlet and connect the output to the power jack on the j-box. 9. Verify that the DM-100 is running. Send a price change to the sign to check communic ations between the sign and the DM-100. Configuring the DM-100 for Gilbarco G -Site Interface Preparation...
Preparation The DM-100 function must be set to GAS PRICE. The current function of the DM-100 is displa yed during power up. To change to function, cycle power to the DM-100, and press the [Set Function] key when prompted. Configuration 1.
Configuring the DM-100 for PAM 1000 Interface Preparation The DM-100 function must be set to GAS PRICE. The current function of the DM-100 is displayed during power up. To change to function, cycle power to the DM-100, and press the [Set Function] key when prompted.
Changing Prices Manually Each display line for which a price category is configured will automatically update when the price is changed in the POS system. Attempting to manually edit prices that are configured for POS control will cause the following screen to appear: THIS LINE POS CTRLD.
Appendix A: Reference Drawings Following are the reference drawings for this manual. The first list contains the general drawings which pertain to all displays. The second list includes drawings that are display specific. These are listed by display size. Reference Drawings Insert, DM-100 Price/T&T Display .................
Need help?
Do you have a question about the DF-2009 Series and is the answer not in the manual?
Questions and answers