3. Load/Save

The set of configuration parameters created in this interface can be saved in a file for use with other ICR-01 Smart Receivers.
In this section you would "save" a configuration file or "load" a file from a location on your computer. Some of the parameters
would still need to be changed (e.g., the IP address).
Load Configuration
Browse for a previously saved ICR-01 Smart Receiver configuration file an load it on this device.
NOTE: Configuration files created on FrontRow devices (e.g. Juno Connect, CM3000) are not compatible between device types.
Save Configuration
Save the configuration file from this device for use on other ICR-01 Smart receivers.
NOTE: Configuration files created on FrontRow devices (e.g. Juno Connect, CM3000) are not compatible between device types.
4. Intercom / PA Audio
These settings are for use when installed with the Conductor IP-based Paging, Intercom and Bell system or with a 29V, 70V, or
100V analog paging system.
Incoming Audio
The PA volume is the volume of incoming audio from Conductor (pages, bells and intercom) and does not affect the volume
of the local (in room) audio. PA Release is the amount of time it takes for the local (in room) audio to return to normal volume
after an incoming audio stream from Conductor.
Outgoing Audio (talk-back)
Gain setting for the audio sent back to the front office from the in-room intercom microphone, i.e. the wall (CB75) or ceiling
(CB85) unit. The gain setting for the pendant microphone when used as the intercom microphone is fixed.
Push to Talk Mode
When used with a CB75 push-to-talk microphone, the push button can be configured in one of three ways:
• Disabled - audio from the in-room microphone can be heard in the front office with no action from the user in the room.
• After push - audio from the in-room microphone can be heard in the front office with no action from the user in the room
until the button is pushed. Thereafter, the user must push the button in the room to activate the microphone.
• Always - audio from the in-room microphone will not be heard until and unless the user in the room is pushing the button.
Analog Page Override
For use with 25V, 70V and 100V analog paging systems. The ICR-01 Smart Receiver will mute all audio in the room when an
announcement is made over the facility's paging system. Analog page override requires a connection to the facility's PA
system. For information about connecting the page override function to the PA system, please see page 20.
Attenuation. Set the attenuation level applied to the audio in the classroom when an announcement is made over the school
PA system. The default setting (10) mutes the in-room audio when an announcement is made.