If your valve requires maintenance or replacement, follow these instructions:
NOTE:
Always shut off the gas and dis-
connect the power supply before
removing the valve.
1) Open the front door and carefully remove
the logs and lava rock.
2) Remove the burner by removing the two
1/4" hex head screws. See diagram below.
3) Open the front pedestal door and unhook
chain. You may want to put a soft cloth on
the base of the unit so that when the pedestal
door is open it doesn't scratch the paint. See
diagram below.
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
REMOVING VALVE TRAY
4) Remove the two outside frame pieces by
removing two screws per side. See diagram
below.
5) Remove the front plate by undoing the 6
screws.
6) Disconnect the manual switch cable and
reset cables.
Manual Switch
Reset Cables
Cable
MAINTENANCE
7) Disconnect the gas pipe line at the valve.
8) Remove the pedestal back cover by remov-
ing the 4 Philips screws.
9) Disconnect the 5 pin molex connector.
10) Disconnect the ground wires.
5 Pin
Molex Connector
11) Remove the 20 x 1/4" hex head screws
holding the burner tray assembly in place.
12) Carefully lift the burner tray assembly out.
13) To replace the burner tray assembly,
reverse these instructions.