Control And Parametrisation Options; Control And Parameterisation Units, Use; Figure 1: Simplebox, Handheld, Sk Csx-3H; Figure 2: Parameterbox, Handheld, Sk Par-3H - Nord Drivesystems NORDAC LINK SK250E-FDS User Manual

Table of Contents

Advertisement

NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) – Users Manual for Frequency Inverters as Field Distributors
Pos: 143 /Anleitungen/Elektronik/FU und Starter/3. Anzeige, Bedienung und Optionen/Bedienung [SK 1xxE, 2xxE, -FDS]/Bedien- und Parametrieroptionen [SK xxxE-FDS] @ 49\mod_1599038560759_388.docx @ 2665927 @ 2 @ 1

3.2 Control and parametrisation options

There are different control options available, installed on the option slots H1 and H2. The required
control options and their functions must be selected upon ordering or during the configuration process
( 2.2.2.2 "Configuration of option slots of the control level"). Retrofitting is not possible.
Parameterisation units furthermore allow for an access to and the adjustment of the device's
parametrisation.
Designation
Control and parameterisation units
SK CSX-3H
SimpleBox
SK PAR-3H
ParameterBox
NORDAC ACCESS BT
SK TIE5-BT-STICK
Bluetooth stick
Pos: 144 /Anleitungen/Elektronik/FU und Starter/3. Anzeige, Bedienung und Optionen/Bedienung [SK 1xxE, 2xxE, -FDS]/Bedien- und Parametrierboxen, Verwendung_01 [SK 1x0E, SK 2xxE, SK xxxE-FDS] @ 48\mod_1597666648135_388.docx @ 2663138 @ 35 @ 1
3.2.1

Control and parameterisation units, use

With an optional SimpleBox or ParameterBox all parameters can be conveniently accessed, read out
or adjusted. The changed parameter data are stored in the non-volatile EEPROM memory.
Up to five complete device data sets can be stored and accessed in the ParameterBox.
SimpleBox or ParameterBox can be connected to the device via an RJ12-RJ12 cable.

Figure 1: SimpleBox, handheld, SK CSX-3H

Module
Used for commissioning,
SK CSX-3H
parameterisation, configuration and
(SimpleBox handheld)
control of the device
Used for commissioning,
parameterisation, configuration and
SK PAR-3H
control of the device and its options
(ParameterBox handheld)
(SK xU4-...). Complete data sets can be
stored.
1)
Does not apply for option modules, e.g. bus interfaces
Connection
1.
Remove the diagnostics glass of the RJ12 socket.
56
Material No.
(handheld)
275281013
275281014
275900120
Description
1)
.

Figure 2: ParameterBox, handheld, SK PAR-3H

Data
4-digit 7-segment LED display, membrane
button
IP20
RJ12-RJ12 cable
(connection to the device
4-line LCD display, backlight, membrane
button
Stores up to five complete parameter data
sets
IP20
RJ12-RJ12 cable (connection to the
device)
USB cable
(connection to PC)
Comment
BU 0040
BU 00040
 BU 0960
1)
)
BU 0250 en-3021

Advertisement