External Connections; Refrigerant Lines - Follett Horizon Elite 1810 Series Installation Instructions Manual

Hide thumbs Also See for Horizon Elite 1810 Series:
Table of Contents

Advertisement

Connect utilities to docking assembly.
6.1
Water and drain
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
. 3/8" push-in connection will be
made at included shut-off valve then at
back of docking station into solenoid.
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Apply Petrogel to barbed drain fitting
• Replace access panel.
BIN • TOP-MOUNT
Minimum 8"
radius
2 ft. x 1" OD
.
.
.
remote condensing

External connections

Chassis drain plumbing - required
• Plug must be removed from John Guest
fitting.
• Route 3/8" drain tubing through knockout
in back of docking station and insert fully
into John Guest fitting connection at the
rear of the machine chassis. Route other
end of 3/8" drain tubing to drain.
• Drain must slope 1/4" inch per foot (6 mm
per 30,4 cm).
6.2

Refrigerant lines

• Braze supplied quick-connect lines onto
stub-ins
.
6
9

Advertisement

Table of Contents
loading

Table of Contents