4.6.9 Cable bending radius, weight and diameter

Table 13: SUBCAB
Cable
4G4 + 2x1.5
4G6 + 2x1.5
4G10 + S(2x0.5)
4G16 + S(2x0.5)
4G25 + S(2x0.5)
4G35 + S(2x0.5)
3x50 + 2G35/2 + S(2x0.5)
3x70 + 2G35/2 + S(2x0.5)
Table 14: SUBCAB
Cable
S3x6 + 3x6/3 + S(4x0.5)
S3x10 + 3x10/3 + S(4x0.5)
S3x16 + 3x16/3 + S(4x0.5)
S3x25 + 3x16/3 + S(4x0.5)
S3x35 + 3x16/3 + S(4x0.5)
S3x50 + 3x25/3 + S(4x0.5)
S3x70 + 3x35/3 +2 S(2x0.5)

4.7 Cable charts

Connection locations
The figures in this section illustrate how to interpret the connection strip symbols.
48
Description
T2 cable lead (control element)
Screen (drain wire)
Power cable to unit
®
Minimum bending
radius in mm
200
240
240
260
320
350
350
380
®
screened cables
Minimum bending
radius in mm
200
240
240
290
320
380
420
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual
control element.
MAS 801: See the SIO manual for T1, T2,
and drain wire connections.
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
0.63
Ø 20.0–22.0
0.83
Ø 24–26
0.85
Ø 24–26
1.13
Ø 26–28
1.70
Ø 32–34
2.24
Ø 35–37
2.6
Ø 35–37
3.3
Ø 38–41
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
0.55
Ø 20–22
0.95
Ø 24–26
1.1
Ø 24–26
1.4
Ø 29–31
2.0
Ø 32–34
3.0
Ø 38–40
3.5
Ø 42–44