13

Descaling

13.1 Conversion from internal Tank to Water Mains

Through this procedure you can change the type
of water supply of the machine, from internal Tank
to Water Mains.
All operations must be performed by technical
personnel only.
• Unplug the machine from the power supply.
• remove the screws and the top cover of the
machine;
• set switch (A) placed on the left side of the ma-
chine to "1";
• replace the top cover of the machine using the
screws;
• insert the knob (B) fitted under the machine and
turn it clockwise (machine seen from below), all
the way down, so that its direction is as shown
in the picture;
• remove the knob and keep it for any future in-
tervention;
• hook the hose (C) supplied to the quick coupling
placed under the machine;
• connect the hose to the water supply and open
the tap (D), make sure that the system pressure
is about 1 bar;
• connect the cable to the power supply and turn
on the machine.
!
All operations must be performed by technical
personnel only.