https://appliancetechmanuals.com
SERVICE
6. Component Replacement – Filter
6.1. Pump and Pump Box
WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER
6.1.1.
Pump Removal
1. Remove Filter Pan and Cover
2. Disconnect pump power cable from rear of
pump box.
3. Remove cabinet rear bottom cover using a
5/16" hex bit.
4. Disconnect pump return hose from return valve
using 1-1/16" wrench.
5. Unscrew filter pickup receptacle and pipe
nipple from pipe coupling using arc joint pliers.
36
CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK
L22-236 Rev. 2 (06/11)
6. Remove pump rod bracket using 5/16" hex bit
7. While supporting pump, remove pump support
rods.
8. Lower and remove pump assembly from
cabinet.
9. Installation is reverse of removal. When
reinstalling filter pickup receptacle, tighten until
receptacle extends 13/16" – 3/4" from cabinet.